If switch/alarm/log/lock all set as ON, When sensor triggered, it will trigger alarm signal and event log, it
will also trigger alarm recording and event recording, besides, the EVENT LOG can
’
t be deleted even
HDD-formatted or overwrite.
HIGH (normal open) means the power level from low to high to trigger the alarm.
ALARM:
Press ENTER to select between OFF or ON:
ON means when sensor triggered, alarm LED will flash, OSD will display in the live view, a red
“
A
”
will
display in each channel, until re-login the system with account, the flashing will disappear, also, MDVR
will record the event log, and, if the security set as OFF, when you trigger the sensor, there is no alarm
LED flashing and MDVR won
’
t record the event log.
LOCK:
To enable the event does not erase during the over-write process of hard disk;
NEXT PAGE:
Sensor trigger action means setup the alarm linkage for each sensor, for example, you setup the
image of channel 1 as the alarm linkage for sensor1, when the alarm from sensor1 is triggered, the image from
channel 1 will change to be full screen. And the priority is from sensor 1 to sensor 8. Sensor1 priority is highest.
Sensor 8 priority is lowest.
3G ACT:
means you can define a sensor to active the 3G module, as there is an active mode in 3G setup interface,
they are corresponding options.
3.2.4.2 SENSOR OUTPUT
MVR-704 MDVR supports 2 sensor outputs. All the alarm inputs can trigger the two sensor outputs, such as
sensor1~8, over speed, temperature, video loss and so on, please access the menu
(GUI>>>>SETUP>>>EVENT>>>SENSOR OUTPUT), as follow:
Remark: Sensor out means when there is an event triggered, the corresponding sensor out will give +12V/2A
output, and the duration is the alarm time you have setup, so, you can associate different sensor to different alarm
types.