4
48
8
© 2005 Directed Electronics, Inc. Vista, CA
2
2--1
11
1 CCH
HA
AN
NN
NEELL 5
5 V
VA
ALLIID
DIITTY
Y//LLA
ATTCCH
HEED
D//LLA
ATTCCH
HEED
D R
REESSEETT W
WIITTH
H IIG
GN
NIITTIIO
ON
N//3
30
0 SSEECCO
ON
ND
D TTIIM
MEED
D//SSEECCO
ON
ND
D U
UN
NLLO
OCCK
K
O
OU
UTTP
PU
UTT:: Channel Four can be programmed for these output configurations. The unit is set to the default valid-
ity output. To change the configuration, use the two-chirp setting to toggle through the different configurations.
3
3--1
1 EEN
NG
GIIN
NEE CCH
HEECCK
KIIN
NG
G O
ON
N//O
OFFFF:: In the default setting the remote start will monitor either the vehicle's tach wire
or voltage depending on the programming of feature 3-2. If programmed OFF the vehicle will crank for the pro-
grammed crank time (feature 3-5) and will not verify with tach or voltage that the car is running. In the OFF
setting, if the vehicle fails to start, the ignition can stay on for the entire run duration. Using tach or voltage
check is always recommended if possible.
3
3--2
2 CCH
HEECCK
KIIN
NG
G TTY
YP
PEE TTA
ACCH
H//V
VO
OLLTTA
AG
GEE:: Selects the method of engine monitoring. If set to TACHOMETER the unit will
reference the learned tach signal to disengage the starter. In addition it will monitor the RPM and shut down if
the engine RPM is too high or too low. When set to VOLTAGE, the unit will crank the starter for the programmed
time and then attempt to sense that the engine is running by detecting an increase in voltage. The threshold
for the voltage check is selectable in feature 3-6.
3
3--3
3 R
RU
UN
N TTIIM
MEE 1
12
2,, 2
24
4,, 6
60
0 M
MIIN
NU
UTTEESS:: Selects the time in minutes that the system will operate the engine
until the system "times out". This is the maximum operation period and the system may be shut down
using a shutdown at any time. Using the Bitwriter®, the run time can be programmed for any duration from 1-
60 minutes.
3
3--4
4 P
PA
AR
RK
KIIN
NG
G LLIIG
GH
HTTSS FFLLA
ASSH
HIIN
NG
G//CCO
ON
NSSTTA
AN
NTT:: In the default setting, the unit will flash the vehicle's parking lights
(if connected) while remote started. The constant setting will turn the parking lights on solid for the entire run
duration.
3
3--5
5 CCR
RA
AN
NK
K TTIIM
MEE 0
0..6
6//0
0..8
8//1
1..0
0//1
1..2
2//1
1..4
4//1
1..6
6//1
1..8
8//2
2..0
0//4
4..0
0 SSEECCO
ON
ND
DSS:: If the unit is programmed for no engine check-
ing or voltage sense, the crank time must be set to the appropriate duration. The default setting is 0.6 second.
If a different crank time is desired, select feature 3-5 and select either 0.6 second by using the one-chirp setting
or toggle through the higher settings by using the two-chirp settings.
3
3--6
6 V
VO
OLLTTA
AG
GEE CCH
HEECCK
K H
HII//LLO
OW
W:: This feature only functions when programmed for voltage sense. Some vehicles have
many accessories, which are turned on when remote started. In these vehicles, the variation of voltage between
the engine off and the car running is very small and the remote start unit may "think" the vehicle has not
started. This can cause the remote start to shut-down after the car has been started. If this happens program
this feature to the LOW position.
3
3--7
7 SSH
HO
OR
RTT R
RU
UN
N//TTU
UR
RB
BO
O:: When the
and
buttons on the transmitter are pressed simultaneously, the
vehicle will start for the programmed short run time. The factory default is 1 minute.
3
3--8
8 A
ACCTTIIV
VA
ATTIIO
ON
N P
PU
ULLSSEE CCO
OU
UN
NTT:: This allows the system to use 1 or 2 pulses to activate the remote start sequence.
m
meennuu ##33 -- rreem
moottee ssttaarrtt ooppttiioonnss