background image

5   

© 2000 Directed Electronics, Inc. Vista, CA

on-board dual stage shock sensor

There is a dual-stage shock sensor inside the control unit. Adjustments are made via the rotary control as indi-

cated in the diagram. Since the shock sensor does not work well when mounted firmly to metal, we do not

recommend screwing down the control module. The full trigger of the on-board shock sensor reports Zone 2. See

the

Table of Zones 

section of this guide.

NOTE:

When adjusting the sensor, it must be in the same mounting location that it will be after

the installation is completed. Adjusting the sensor and then relocating the module requires read-
justment.

optional sensor harness, 4-pin connector

The four-pin sensor harness is optional, and is not included with this unit.

These wires supply constant 12 volts and ground to the optional sensor.

These wires are multiplex inputs. If a (-) input of less than 0.8 seconds is supplied to either wire, the Warn-Away

response will occur. A (-) input of longer than 0.8 seconds to either wire will initiate the triggered sequence and

report Zone 4.

BLUE, GREEN

RED, BLACK

Summary of Contents for 420ESP

Page 1: ...opping DEI Doubleguard ESP FailSafe Ghost Switch Learn Routine Nite Lite Nuisance Prevention Circuitry NPC Revenger Silent Mode Soft Chirp Stinger Valet Vehicle Recovery System VRS and Warn Away are a...

Page 2: ...IREN OUTPUT YELLOW SWITCHED IGNITION INPUT ZONE 5 BLACK CHASSIS GROUND INPUT VIOLET DOOR TRIGGER INPUT ZONE 3 BLUE INSTANT TRIGGER INPUT ZONE 1 GREEN DOOR TRIGGER INPUT ZONE 3 BLACK WHITE 200 mA DOMEL...

Page 3: ...ut any additional parts With certain vehicles or if an actuator is to be installed either a p n 451M Door Lock Relay Satellite or two relays will be required IMPORTANT If you mistake a Type C direct w...

Page 4: ...arance before drilling a 9 32 inch hole and mounting the switch The GRAY wire in the two pin plug may also be used as a ghost switch input and can be connected to any switch in the vehicle See Feature...

Page 5: ...TE When adjusting the sensor it must be in the same mounting location that it will be after the installation is completed Adjusting the sensor and then relocating the module requires read justment opt...

Page 6: ...hen you need to temporarily bypass all sensor inputs to the unit such as when remote start ing the vehicle Anytime an auxiliary channel output is used all inputs are bypassed for 5 seconds During the...

Page 7: ...n Turn the ignition on then back off The H1 9 YELLOW wire must be connected 3 Select a Menu Press and HOLD the Valet Program button The Valet Program button must be plugged into the blue port After th...

Page 8: ...es and then press it once more and HOLD it The siren would chirp seven times to confirm access to the seventh feature 1 Press and HOLD the Valet Program switch 2 After three seconds the unit will adva...

Page 9: ...rolled domelight OFF 2 8 Single unlock pulse Double unlock pulse 2 9 Channel 3 Validity Channel 3 latched latched reset with ignition 30 second timed second unlock output menu 2 advanced features FEAT...

Page 10: ...ssive arming is selected in step 1 1 then the system can be programmed to either lock the doors when passive arming occurs or only lock the doors when the system is armed via the transmitter Active lo...

Page 11: ...riggered This is useful to honk the factory horn in applications where a siren is undesirable Remember that the unit is only capable of supplying 1 amp of current A relay will be required to interface...

Page 12: ...ON OFF With the door trigger error chirp programmed off the system will not report an invalid zone on arming when the door trigger wire is active This eliminates the extra chirps that occur when inte...

Page 13: ...ire must be connected 2 Key Turn the ignition on The YELLOW wire H1 9 must be connected 3 Select the receiver channel Press and release the Valet Program button the number of times necessary to access...

Page 14: ...red into channel one the remote will be erased from memory and the system will only recognize the button that was entered into channel one Channel 9 If any transmitter button from a known transmitter...

Page 15: ...systems that use sepa rate remote transmitter buttons for the arm disarm panic and auxiliary output functions operates Arm only operates Disarm only operates Channel 2 operates Panic and operate Chan...

Page 16: ...16 2000 Directed Electronics Inc Vista CA wiring quick reference guide...