background image

© 2000 Directed Electronics, Inc. Vista, CA  

2

primary harness (H1), 12-pin connector

______

______

______

______

______

______

______

______

______

______

______

______

RED/WHITE

(-) 200 

mA CHANNEL 2 OUTPUT

RED

(+) CONSTANT POWER INPUT

BROWN

(+) SIREN OUTPUT 

YELLOW

(+) SWITCHED IGNITION INPUT, ZONE 5

BLACK 

(-) CHASSIS GROUND INPUT 

VIOLET 

(+) DOOR TRIGGER INPUT, ZONE 3 

BLUE

(-) INSTANT TRIGGER INPUT, ZONE 1 

GREEN

(-) DOOR TRIGGER INPUT, ZONE 3

BLACK/WHITE

(-) 200 

mA DOMELIGHT SUPERVISION OUTPUT 

WHITE/BLUE

(-) 200 

mA CHANNEL 3 PROGRAMMABLE OUTPUT

WHITE

(+)/(-) SELECTABLE LIGHT FLASH OUTPUT

ORANGE

(-) 500 

mA ARMED OUTPUT 

H1/1

H1/2

H1/3

H1/4

H1/5

H1/6

H1/7

H1/8

H1/9

H1/10

H1/11

H1/12

primary harness wiring diagram

Summary of Contents for 420ESP

Page 1: ...opping DEI Doubleguard ESP FailSafe Ghost Switch Learn Routine Nite Lite Nuisance Prevention Circuitry NPC Revenger Silent Mode Soft Chirp Stinger Valet Vehicle Recovery System VRS and Warn Away are a...

Page 2: ...IREN OUTPUT YELLOW SWITCHED IGNITION INPUT ZONE 5 BLACK CHASSIS GROUND INPUT VIOLET DOOR TRIGGER INPUT ZONE 3 BLUE INSTANT TRIGGER INPUT ZONE 1 GREEN DOOR TRIGGER INPUT ZONE 3 BLACK WHITE 200 mA DOMEL...

Page 3: ...ut any additional parts With certain vehicles or if an actuator is to be installed either a p n 451M Door Lock Relay Satellite or two relays will be required IMPORTANT If you mistake a Type C direct w...

Page 4: ...arance before drilling a 9 32 inch hole and mounting the switch The GRAY wire in the two pin plug may also be used as a ghost switch input and can be connected to any switch in the vehicle See Feature...

Page 5: ...TE When adjusting the sensor it must be in the same mounting location that it will be after the installation is completed Adjusting the sensor and then relocating the module requires read justment opt...

Page 6: ...hen you need to temporarily bypass all sensor inputs to the unit such as when remote start ing the vehicle Anytime an auxiliary channel output is used all inputs are bypassed for 5 seconds During the...

Page 7: ...n Turn the ignition on then back off The H1 9 YELLOW wire must be connected 3 Select a Menu Press and HOLD the Valet Program button The Valet Program button must be plugged into the blue port After th...

Page 8: ...es and then press it once more and HOLD it The siren would chirp seven times to confirm access to the seventh feature 1 Press and HOLD the Valet Program switch 2 After three seconds the unit will adva...

Page 9: ...rolled domelight OFF 2 8 Single unlock pulse Double unlock pulse 2 9 Channel 3 Validity Channel 3 latched latched reset with ignition 30 second timed second unlock output menu 2 advanced features FEAT...

Page 10: ...ssive arming is selected in step 1 1 then the system can be programmed to either lock the doors when passive arming occurs or only lock the doors when the system is armed via the transmitter Active lo...

Page 11: ...riggered This is useful to honk the factory horn in applications where a siren is undesirable Remember that the unit is only capable of supplying 1 amp of current A relay will be required to interface...

Page 12: ...ON OFF With the door trigger error chirp programmed off the system will not report an invalid zone on arming when the door trigger wire is active This eliminates the extra chirps that occur when inte...

Page 13: ...ire must be connected 2 Key Turn the ignition on The YELLOW wire H1 9 must be connected 3 Select the receiver channel Press and release the Valet Program button the number of times necessary to access...

Page 14: ...red into channel one the remote will be erased from memory and the system will only recognize the button that was entered into channel one Channel 9 If any transmitter button from a known transmitter...

Page 15: ...systems that use sepa rate remote transmitter buttons for the arm disarm panic and auxiliary output functions operates Arm only operates Disarm only operates Channel 2 operates Panic and operate Chan...

Page 16: ...16 2000 Directed Electronics Inc Vista CA wiring quick reference guide...