Violet Defense Vantage I User Manual & Warranty Download Page 4

1.  Read these instructions prior to operating the unit.  For the most up-to-date manual, visit www.

violetdefense.com/resources. 

2. 

Heed all warnings.  Failure to use the equipment in the manner specified may impair the unit from 

providing the desired protection.

3.  THIS EQUIPMENT IS DESIGNED FOR USE WITH GERMICIDAL LAMPS OR UV SOURCES.  STRICT 

ADHERENCE TO THE INSTALLATION DIRECTIONS IS NECESSARY TO PREVENT OCCUPANT 

EYE AND SKIN EXPOSURE TO HARMFUL RADIATION.

4.  This equipment is designed for use with germicidal UV radiation sources and must be installed 

in compliance with competent technical directions to prevent risk of personal injury from UV 

radiation.

5.  UV radiation can pose a risk of personal injury.  Overexposure can result in damage to eyes and 

bare skin.  To reduce the risk of overexposure this equipment must be installed in accordance with 

the manufacturer’s site planning recommendations, including instructions on relative location 

of each germicidal system component, the minimum distances between UV-generating devices 

and other objects or surfaces, and protection from line-of-sight exposure to UV radiation in 

unoccupied spaces located above the equipment mounting area (e.g. upper floor balconies, open 

staircases, etc.).

6. 

UV and optical radiation can be reflected by surrounding surfaces such as ceilings and walls.  Since 

reflective properties of surfaces can vary widely, it should be considered as part of site planning.  

Follow the manufacturer’s recommendations for selecting appropriate ceiling and wall finishes.

7.  IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE THAT PERSONS WILL NOT BE 

EXPOSED TO EXCESSIVE UV OR OPTICAL RADIATION DURING EQUIPMENT OPERATION.  THIS 

WILL REQUIRE THE INSTALLER TO CONDUCT AN ASSESSMENT OF ALL SITE AND EQUIPMENT 

SAFEGUARDS TO ENSURE THE SYSTEM IS OPERATING IN ACCORDANCE WITH THE SYSTEM 

MANUFACTURER’S INSTRUCTIONS, INCLUDING AN ASSESSMENT OF IRRADIANCE OR 

ILLUMINANCE LEVELS IN THE SURROUNDING OCCUPIED SPACES.

8.  Equipment should be mounted in locations and at heights where it will not readily be subjected to 

tampering by unauthorized personnel.  

9.  Equipment contains no user serviceable components.  Contact Violet Defense for service. 

Maintenance and servicing of this UV generating equipment shall be performed by authorized 

personnel.  Service personnel must wear appropriate Personal Protective Equipment (PPE) if the 

equipment will be in operation during the maintenance or servicing work.  Contact the equipment 

manufacturer for PPE recommendations and guidance.

10. The use of accessory equipment not recommended by the manufacturer may cause an unsafe 

condition.

11. Do not use this equipment for other than intended use. 

12. Plug unit into a grounded outlet.  Ensure proper conditions for operation.  The unit is designed 

to operate under normal conditions indoors (temperature 5-40 degrees Celsius, RH less than 

80% (non-condensing), at an altitude <2000m and main supply fluctu/- 10% of nominal 

voltage, overvoltage Category II.

13. 

Allow unit to complete pre-programmed cycles prior to unplugging or shutting off power.  This 

allows it to enter safe mode.

2

Summary of Contents for Vantage I

Page 1: ...USER MANUAL WARRANTY Vantage I Vantage II Violet Defense LLC www violetdefense com 1 407 433 1104 Copyright 2021 Violet Defense LLC All Rights Reserved VNTG USRMNL 2021...

Page 2: ...NS FOR USE 4 STANDARD UNITS OPERATIONAL GUIDELINES 5 BUILDING AUTOMATION ENABLED UNITS OPERATIONAL GUIDELINES 6 RECOMMENDED CLEANING PROTOCOLS 11 TROUBLESHOOTING 12 INSTALLATION 13 UV GOVERNMENT GUIDE...

Page 3: ...he programming on the Vantage UV units over a 30 minute cycle time for the unit the actual exposure to UV if there were no other safety systems in place would be no more than two seconds of exposure M...

Page 4: ...ng Follow the manufacturer s recommendations for selecting appropriate ceiling and wall finishes 7 IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE THAT PERSONS WILL NOT BE EXPOSED TO EXCESSIVE UV...

Page 5: ...nce in which case the user will be required to correct the interference at his own expense 14 Do not allow the unit to get wet or be used in or near water 15 Do not block any ventilation openings Use...

Page 6: ...ected in the space The unit will resume operation approximately 60 seconds unless alternate motion timeout was selected after room is unoccupied and no additional motion is detected If any issues are...

Page 7: ...utomatically activate once the space is unoccupied and continue disinfection on a regular schedule adjusting frequency based on level of activity in the space based on the motion sensor Users may sele...

Page 8: ...the safety features or have an acceptable alternative control to prevent occupant exposure to the UV light With the building automation capabilities of the Vantage UV Whole Room Unit users have the ab...

Page 9: ...ion method Verify each step carefully If it is still not responding try rebooting the unit or using the reset pinhole located next to the unit power source to restore the default memories 2 The unit s...

Page 10: ...t cleans for in manual mode Range 1 minutes to 30 minutes Motion Timeout STPT Sets the number of seconds for which the unit will pause when it detects motion Range 15 seconds to 1800 sec onds Enable C...

Page 11: ...be set here Subnet Mask CNFG If DHCP is disabled a static subnet mask can be set here Gateway CNFG If DHCP is disabled a static gateway can be set here Device MAC Address CNFG The Vantage unit s MAC...

Page 12: ...nth Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Hour when time changes in 24 hour format A dash separator must be used between the start rule and end rule For example in the United States DST star...

Page 13: ...V unit prior to commencing any cleaning procedures If the blood has already dried apply hydrogen peroxide solution prior to running the unit 2 Utilize normal procedures including appropriate safety pr...

Page 14: ...rsonnel Hazardous voltages may be present Each Vantage UV unit has indicator lights that help you determine the status of the unit CLEANING THE UNIT Do not use abrasive cleaners to clean the unit To c...

Page 15: ...se a box cutter or other appropriate tool to cut off the 5 3 4 section of the tile 5 Secure the unit using tie wires following proper electrical and building codes 6 Position the Vantage unit onto cei...

Page 16: ...he ceiling ensuring the anchors match up to the holes 5 Tighten the toggle bolt anchors Assembling Hard Ceiling Kit 6 Place the Vantage unit face down making sure that the light engine and occupancy s...

Page 17: ...kits for additional information PORTABLE DEPLOYMENT Copyright 2021 Violet Defense LLC All Rights Reserved VNTG USRMNL 2021 15 WALL MOUNTED DEPLOYMENT The Vantage units can also be used in various roo...

Page 18: ...ds associated with skin exposure are of less importance than eye hazards Exposure to light may cause photokeratitis or cataracts National Institute for Occupational Safety and Health NIOSH The Nationa...

Page 19: ...CONTACT US Violet Defense 189 S Orange Avenue Suite 1400 Orlando FL 32801 info violetdefense com 1 407 433 1104...