29
Maintenance
2.
Remove the load, release the bottom clamp (21) and set the bottom
stage (7) to its maximum height.
Both stages must be fully
extended and the payload removed.
3.
Tip the pedestal over and carefully lay it on its side.
4.
Unscrew and remove the centre end plug (23) from the base of the
telescopic column.
5.
Withdraw the gas strut (24) from the column.
6.
Fit the new gas strut, cylinder end first, carefully guiding it up
through the column until it is fully engaged.
7.
The strut is correctly fitted when the thread on the end plug (23)
can be started in the column without compressing the strut.
8.
Tighten the end plug.
9.
Carefully stand the pedestal upright.
21
14
14
14
19
18
23
24
!
WARNING!
Make sure that the pedestal is at it’s
maximum height before tipping it over and removing the
centre plug. If not
do not
attempt to remove the nut (23)
as the strut will be ejected under pressure.
Strut
Payload / Force Part No.
Factory Fitted
30-55 kgs / 450N
3328--305
Supplied loose with Pedestal
55-70 kgs / 600N
3328-385
Available to purchase
0-30kgs / 270N
3328-307