g. Low
voltage.
h. Operating 60 Hz unit at 50Hz
i. Sealed
system
problem
j. Undercharge or overcharge
installation
g. Check power supply
h. Use proper 60 Hz
i. Check for loss of refrigerant or
restrictions
j. Add or remove refrigerant
7. House circuit tripping
a. Incorrect fuse or breaker
b. Incorrect
wirings
c. Malfunctioning
components
a. Check for proper fuse or breaker
b. Check wirings and connections
c. Check
failed
components
8. Noisy operation
a. Mounting area not firm
b. Loose
parts
c. Compressor overloaded due to
high ambient temperatures or
airflow restriction
d. Malfunctioning
components
a. Add support to improve installation
b. Check fan blades, bearings, cabinet
washers, tubing contact and loose
screws.
c. Check for airflow blockage
d. Check for internal loose, inadequate
lubrication and incorrect wirings
- 20 -