-17-
Fig. 5 WM-250~650SCUR-WC Condensing Unit
Fig. 6 WM-Liquid Filter
Fig. 7 WM-Liquid Indicator
2. Temperature Controller and Air Probe Location
1) The temperature controller can be mounted either inside or outside the wine
cellar, but the air probe must be located inside the wine cellar or the return duct.
2) The air probe shall be located in the wine cellar 5 ft above the floor or the air
return area, but it shall not be located in the air supply area or other areas
where air is not circulated.
3) Air probe can be pulled out of the temperature controller up to 5 ft. If additional
wires are necessary, 18 gauge wires may be used to extend the air probe.
4) If the air probe is installed in a return duct, the evaporator fans shall be running
all the time. Meanwhile due to the temperature differential the air probe
calibration should be done in order to maintain the proper wine cellar
temperature.
3. Evaporator Unit Location