Dispensing System
Complaint
Possible Causes
Response
Unit not
dispensing
a) Gas empty
b) Gas tubing blockage
c) Stopper/dispenser not
tightened
d) Stopper-dispenser & tubes
not connected
e) Wine draw not installed
f) Defective solenoid valve
g) Defective stopper- dispenser
h) Incorrect or loose wiring.
a) Check pressure gauge or push the
coupling plug to see if gas is
escaping.
b) Check for kinked tubes or press
dispensing button to see if gas is
escaping
c) Check bottle neck connection
d) Check for tube and coupling
connections
e) Check wine draws
f) Check solenoid valve
g) Check stopper-dispenser
h) Check all wiring and connections
Dispensing
interrupted or
slow
a) Gas pressure low
b) Tubes kinked, twisted
c) Bottle neck leak
d) Solenoid valve restricted
e) Stopper-dispenser blocked
f) Inline filter dirty
a) Adjust the pressure or change cylinder
b) Check tubes
c) Check stopper-dispenser seal
d) Clean solenoid valves
e) Clean parts
f) Change inline filter
Wine spurting or
spitting
a) Wine draw leak at the
stopper-dispenser
b) Wine draw restricted
c) Bottle near empty and too
much gas in the bottle
d) Gas pressure too high
e) Stopper-dispenser
internal
leak
f) Solenoid valve is dirty
a) Tighten the wine draw onto the
stopper-dispenser
b) Check for any restrictions
c) Change bottles
d) Reduce the pressure to 3-5 psig
e) Change new stopper-dispenser
f) Clean solenoid valves
Wine dripping
a) Solenoid valve seat leak
b) Spout leak at solenoid valve
fitting
a) Check for debris if continuous dripping
b) Push to tighten spout if intermittent
dripping
Wine drop
forming at spout
a) Wine draw loose or leaking
b) Stopper-dispenser
internal
leak
c) Wine
bottle
empty
d) Gas pressure too low
a) Check wine draw
b) Change the part
c) Change bottle
d) Increase the pressure or change
cylinders
Wine divided
a) Debris in spout
a) Clean out debris
Too many
bubbles in wine
a) Gas pressure too high
a) Reduce the gas pressure to 3-5 psig
Stopper-
dispenser leaking
a) Stopper-dispenser not
installed properly
b) Stopper-dispenser worn-out
c) Gas pressure too high
a) Reinstall the stopper-dispenser
b) Replace the part
c) Reduce the gas pressure to 3-5 psig