Clean Condenser
•
The condenser coil is black serpentine tubing that is located behind the front
grille. Condenser coil may need to be cleaned at least every 6 months.
•
Use a vacuum cleaner with an extended attachment to clean the condenser coil
when it is dusty or dirty.
Cleaning the dispensing system
•
Fill a bottle with clean warm water and tighten the stopper-dispenser.
•
Press and hold the dispensing button to dispense the warm water.
•
Continue to flush the system until only dry gas escapes out of the spout.
Changing the LED light
•
Remove the 3 cover screws.
•
Disconnect the wire plug and socket.
•
Remove the LED PCB from the
cover.
•
Use the reverse steps to place a new
one.
Normal Operating Sounds
•
You may hear a boiling or gurgling sound produced by flow of refrigerant through
the evaporator.
•
You may hear air being forced through the unit by the evaporator fan.
•
You may hear air being forced through the condenser by the condenser fan.
•
You may hear a clicking sound produced by the refrigerant valve and dispensing
valve.
•
You may hear a water dripping sound during automatic defrost cycle.
•
You may hear a high pitched hum or pulsating sound produced by the
compressor.