36
b
a
c
45 mm
a
7602040
FIG.54
FIG.55
Now, reset the clinometer by making a jumper on the
rear of the card (Fig. 53/a); the sound of the card indi-
cates that the setting is in progress.
Press the “bell” push-button.
Remove the jumper.
The buzzer will indicate when the reset is completed.
12) PREPARING THE LIFT FOR SETUP
When installation of the lift’s mechanical parts is com-
plete, the on-board control panel (Fig. 54/a) must be
added to the installer card (Fig. 54/b).
Reset the lift using the switch provided (Fig. 54/c), re-
move the magnet from where it was placed temporarily,
then press the down button on the on-board control
panel; the lift will now descend at low speed, looking for
the magnet, which must be placed on the rail in such
a position that the home floor sensor detects it in line
with the exact access position (all subsequent opera-
tions will take the position of this magnet as reference).
Glue the magnet (Fig. 55/a) supplied to the bottom end
of the top rail as shown in Fig. 55.