7
7511131
3.6) Reference technical norms
The stairlift complies with the following norms:
- Directive 2004/108/CEE “Electromagnetic Compa-
tibility”
- Directive 2006/95/CEE “Low Voltage”
- Directive 2006/42/CEE “Machinery Directive”
- Drive system
Irreversible worm gear
Ratio 1/80
-
Performance levels
Travel direction
Forward/back
Speed (up/down)
0.07 m/s
Capacity
1 person
Gradient
from 0° to 50°
Load capacity
V64/74
- 300 kg for platform with P ≤770 and gradient up to 45°
- 250 kg for platform with P >770 and gradient up to 45°
- 200 kg with gradient between 45° and 50°
-
Duty cycles
Normal service
20 min/hour max.
-
Ambient conditions
Temperature
From -10°C to +60°C
Humidity
maximum 70% (use in bathrooms and swimming-
pools is not permitted)
-
Electric system
Drive motor
230 VAC single-phase 50 Hz - 0.75 kW
Absorption
8 A
Circuit-breaker
-
Controls
Up/down/stop button
Timed (starting delay 2 seconds)
Emergency stop button with detent
(immediate stop)
Key-switch
Circuit-breaker reset button (to be
provided by the customer).
4) ) TECHNICAL SPECIFICATIONS
7512131
Summary of Contents for V 64
Page 44: ...44 SAFETY BARS ...
Page 47: ...47 RETRACTABLE SAFETY BARS ...
Page 50: ...50 GUARDS ONLY FOR MOD V64 ONLY FOR MOD V74 ...
Page 52: ...52 6 9 8 7 10 4 2 1 7 7 1 2 11 13 12 1 2 5 3 RAIL ...
Page 54: ...54 14 5 8 9 2 3 11 6 10 13 4 1 7 12 2 15 ELECTRICAL PANEL B I ...
Page 58: ...58 1 2 3 4 FOOTREST GUARD BOARD DRIVE CABLES INDEPENDENT BARS RETRACTABLE BARS ...
Page 60: ...60 2 4 1 3 5 6 CONTROL BOARDS ...
Page 62: ...62 ...
Page 63: ...63 ...
Page 64: ...64 ...