Preliminary procedures
Note
: The BASIC configurations can be assigned manually in
BASIC mode )as described below( or ADVANCED mode with the
SaveProg software complete with interface, installed on a PC.
All CONFIGURATION operations must be performed with
the indoor station on standby
.
The indoor stations, after being installed as shown in the pre-
vious chapters, must be configured by assigning the ID code.
The ID code is unique for each appliance.
Manual ID code configurations
The Basic indoor station configurations are as follows:
- Configuration of the
ID code.
- Or configuration of the
secondary
ID code
, to be done when
an indoor station needs to be associated with a
Master
indoor
station.
Configuration of the ID code
The identification code is programmed with a configured MAS
-
TER entrance panel.
An indoor station with no ID code configuration beeps three
times when the
button is pressed
1) Press and hold down the
button.
2) Press the
button too and keep them pressed until the
button starts blinking.
3) Release the buttons.
4) Press the
button within 5s and keep it pressed until you
hear a warning tone on the indoor station and the communi-
cation is activated between the indoor station and the exter-
nal electronic unit. If more than 5s passes without the
button being pressed, steps 1, 2 and 3 must be repeated.
5) Release the
button.
6) With a timeout of 30s associate the ID code from the external
electronic unit:
- if using an alphanumeric entrance panel, enter the primary
ID code and confirm with the
button.
- if using an entrance panel with buttons, press the button
you want to use for calling the indoor station.
Note
: If the system already contains an indoor station with the
same associated identification code, the entrance panel emits
a low tone and the process must be repeated from the start in
order to assign a different code.
Configuring the secondary ID code in automatic
mode
The
secondary
identification code is configured when the same
call has to activate multiple indoor stations at the same time
)max 4 composed of 1 Master and 3 secondary ones(. You need
to define a
Master
indoor station which can be associated with
up to 3 indoor stations with a
secondary
ID. At most 50
Master
ID codes can be configured in this mode.
1) Press and hold down the button
of the
Master
indoor
station.
2) Press the
button too and keep them pressed until the
button starts blinking.
3) Release the buttons.
4) Press the
and
buttons simultaneously and keep
them pressed until you hear a warning tone on the indoor sta-
tion and the communication is activated between the indoor
station and the external electronic unit. If more than 5s pass-
es without the
and
buttons being pressed, steps 1,
2 and 3 must be repeated.
5) Release the
and
buttons.
6) With a timeout of 30s associate the ID code of the
Master
from the external electronic unit:
- if using an alphanumeric entrance panel, enter the Master
ID code and confirm with the
button.
- if using an entrance panel with buttons, press the button
you want to use for calling the indoor station.
Note: The SaveProg software can be used to program activation
of the chimes of all the monitors and switching on the monitor of
only the master unit.
Note: To delete from a group, the configuration deletion proce
-
dure described in the “Default data restore procedure” section
must be performed.
Default data restore procedure
1) Press and hold down the button
2) Press the button
too and keep them pressed until the
button
starts blinking.
3) Release the buttons.
4) Press and hold down the button
.
5( When an audible warning is emitted )during the sound( re
-
lease the button
and briefly press the button
.
The indoor station configurations have now been de
-
leted. Make sure that the configurations have been
successful deleted by pressing the button.
.
The indoor station should emit an audible warning )3 beeps(.
18
TAB:
7539
EN