![Vimar ELVOX RS02 Connection And Operating Manual Download Page 31](http://html1.mh-extra.com/html/vimar/elvox-rs02/elvox-rs02_connection-and-operating-manual_1026954031.webp)
29
RS02
4.8- Connecting the aerial
The 17 cm rod is supplied pre-wired, to increase the range connect the aerial art. ZL43, as shown in the figure:
5 - Description of the LEDs in the circuit
Buttons in the circuit
Abbreviation
Description
AP/CH
Controls opening and closing the gate/barrier
ESC
Exit or go back to the lower level of the menu
UP
Increases the displayed value by one unit or scrolling on the same menu level
DOWN
Decreases the displayed value by one unit or scrolling on the same menu level
ENTER
Confirms the value or moves to the top level of the menu, when pressed while the gate/barrier is moving it shows the absorp-
tion of the electric motor in Amps
Preliminary check:
After powering up the control panel, the display shows the name of the control panel RS02, the firmware version Fxxx and 3 flashes with the words FLSH and
then switches off. Check the diagnostic LEDs of the inputs, the STOP, FOTO, STPA, FCAP and FCCH LEDs must be on (if the limit switches are not engaged).
Should one of the safety inputs (FOTO, STOP, STPA) not be used, insert a jumper between COM and the input not used.
Fig. 12
Abbreviation
Description
AC
Shows whether there is mains power (lit if there is mains voltage)
STPA
Displays the status of the STPA input (terminal 16), if not engaged the green LED remains lit, if not used then jumper be-
tween terminal COM and STPA
AP/CH
Displays the status of the AP/CH input (terminal 11), if not engaged the red LED remains off
APED
Displays the status of the APED input (terminal 12), if not engaged the red LED remains off
STOP
Displays the status of the STOP input (terminal 14), if not engaged the green LED remains lit, if not used then jumper be-
tween terminal COM and STOP
PHOTO
Displays the status of the FOTO input (terminal 15), if not engaged the green LED remains lit, if not used then jumper be-
tween terminal COM and FOTO.
FCAP
Displays the status of the opening limit switch with parameter 31 off, the green LED goes out when the gate/barrier is fully
open. Displays the status of the closing limit switch with parameter 31 on, the green LED goes out when the gate/barrier is
fully closed (OPTIONAL).
FCCH
Displays the status of the closing limit switch with parameter 31 off, the green LED goes out when the gate/barrier is fully
closed. Displays the status of the opening limit switch with parameter 31 on, the green LED goes out when the gate/barrier
is fully open (OPTIONAL).
ENC.A
Displays the encoder A input, on steady when the motor is moving at cyclical speed, flashing during slowdown, off with the
motor stopped.
ENC.B
Displays the encoder B input, on steady when the motor is moving at cyclical speed, flashing during slowdown, off with the
motor stopped.
PROGRAM MENU DISPLAY Displays the programming menu
6 - Set the type of actuator
DSW1.1 = OFF function as sliding
DSW1.1 = ON operation as a road barrier
EN