DESCRIPTION OF SWITCHBOARD KEYPAD

The switchboard is equipped with a 20-key keypad divided into two sections: the right hand section is used to make calls,
program the switchboard and cancel operations currently in progress. The left hand zone is instead used to activate porter’s
call, door lock release, intercom, conference, call transfer to internal unit and notification functions.

DESCRIPTION OF KEYPAD

Left hand section:

Button MEMORY 

SCROLL: 

Use to scroll calls from interphones or monitors

Button 

DOOR LOCK RELEASE: 
Activates terminal S on the switchboard and opens the door lock at the main entrance panel communicating
with the switchboard. 

Button TRANSFER:

Transfers the number in order to make a call to an internal unit, activate the intercom or conference function or
cancel the number.

Button TELEPHONE:

This button is used to connect the telephone line (terminals a-b) to the interphone cable riser.

Button INTERCOM:

This function enables conversation between two users: two interphones (monitors) or interphone (monitor) and
entrance panel. Intercommunicating, conferencing or conversations between the entrance panel and interpho-
ne (monitor) are indicated by illumination of the lamp "INTERC."

Button CONFERENCE:

This function enables conversation between two or three users (interphones or monitors). Activation of the
conferencing function is indicated by illumination of the lamp "INTERC.".

Button INTERNAL/EXTERNAL:

Use to manually switch the switchboard from internal to external mode and vice versa.
Illumination of the lamp"EXTERNAL" indicates that the switchboard is in external mode.

Button NOTIFICATION:

This button allows the switchboard to enter a conversation already in progress. An acoustic signal announces
activation of this function to users. 

Right hand section:

Button 0-9 

NUMBER SELECTION:
Use to enter user call numbers and change technical parameter settings during switchboard programming
operations.

Button R 

DISPLAY ZERO SET:
Cancels and interrupts all conversations. This button is also used to exit the technical parameter program-
ming function.

Button USER 

CALL:

Routes the call once the number has been entered. In technical parameter programming mode, this button is
also used to confirm any changes made to settings and pass onto the next parameter.

Buttons R and 4PROGRAMMING ACCESS:

Press these buttons simultaneously to enter the technical parameter programming function. 

Keypad lamps in central section of switchboard:

LINE:

The light indicator is lit on the audio line (Terminal 3) when there is at least one set connected and
unhooked.  The light indicator is also lit when there is a call signal on the audio line. 

Interc.: 

The light indicator is lit when two  or more interphones (monitors)  or an interphone (monitor) and a door
entry panel are communicating together.

External:

When the light indicator is switched off the switchboard is in "internal" mode, otherwise is in "external"
mode.

Summary of Contents for ELVOX 945B

Page 1: ...945B 945B I Porter s Switchboard Installer guide...

Page 2: ...ries of states functions ICON DESCRIPTION box with an arrow followed by a number It shows that there are calls or other commands in the memory 5 number of queued calls Telephone handset It means the h...

Page 3: ...musical melodies by means of a special software and an interface connec ted to a personal computer SOFTWARE LOCK KEY The switchboard keypad may be locked by means of the software key SIMPLIFIED MANAGE...

Page 4: ...igns a code to the switchboard for direct call from entrance panel or remote programming 1 99999999 00000000 Not used Technical prg key 0 9999 00000123 Technical programming access code Dis switch key...

Page 5: ...ault password 27 The switchboard keypad is now blocked The display shows the message BLOCCO CHIAVE locked keypad Transit and calls toward the switchboard are in any case completely active To release i...

Page 6: ...According to display press 1 to activate the printing of CALLS FROM INTERPHONE CH Calls from interphone 2 for commands F1 4 for commands F2 8 for lock release LOCK and 16 for all calls made by the swi...

Page 7: ...t print the lines you can attempt to add such character entering parameter PRINTER SETUP 16 With ink jet printers or similar it is not usually possible to print the single lines one at time Such print...

Page 8: ...tion is used to reduce the melody time dwell when it is too long DOWNLOADING A NEW MELODY There are two possibilities 1 With proper software through serial interface The software consists of a musical...

Page 9: ...ated by illumination of the lamp INTERC Button INTERNAL EXTERNAL Use to manually switch the switchboard from internal to external mode and vice versa Illumination of the lamp EXTERNAL indicates that t...

Page 10: ...ed user is number and press the bell button After placing the call the switchboard will con nect its phonic line and activate its video camera and monitor which displays the image filmed by the switch...

Page 11: ...y one by entering the corresponding number and pressing but ton Each time button is pressed the switchboard routes the call to an internal unit without disconnecting those already connected In confere...

Page 12: ...ctivation of auxiliary function 2 3C Acoustic call terminal 4 Supply voltage negative terminal 5 Supply voltage terminal 13 5 Vdc R e R Additional bell connection terminals I Terminal controlling moni...

Page 13: ...10 18 10 Resistance 100m 14 00 6 60 4 80 3 50 2 20 1 70 1 14 0 69 0 39 0 28 Conversion table of sections diameters and relative resistances for 100 m standard conductors INTERPHONE RISER WITH FLOOR DI...

Page 14: ...J1 C J1 CO C CO 3 6 2 5 9 0 8 M 1 4 7 LINE POWER Interc In Out Interc2 Line2 R R 88888888 8 7 R 0 4 1 2 5 9 C 3 6 14 SIMPLE RESIDENTIAL INSTALLATION WITH PORTER S SWITCHBOARD Ref diagram si091 INTERPH...

Page 15: ...4 P L L P L P J1 C J1 CO J1 C J1 C C C C CO R R Line2 Interc2 In Out Interc POWER LINE 7 4 1 M 8 0 9 5 2 6 3 88888888 8 7 R 0 4 1 2 5 9 C 3 6 15 RESIDENTIAL INTERPHONE INSTALLATION WITH ONE MAIN PANE...

Page 16: ...t 6714 Monitor Art 6304 Art 6304 C Art 6504 Art 6324 Art 6324 C Art 6344 Art 6354 16 MONITOR CABLE RISER WITH UNITS EQUIPPED WITH INTERNAL DIGITAL SIGNAL DECODING Ref diagram si356 Monitor Art 6023 Ar...

Page 17: ...hm CN1 Monitor Art 6307 Art 6507 Art 6307 C Art 6327 Art 6527 C Monitor Art 6627 Art 662B Art 6727 17 TO POWER SUPPLY ART 6948 Distributor Art 5556 004 5555 MONITOR CABLE RISER A Distributor Art 949B...

Page 18: ...DO SR V 1 4 3 5 SR 5 3 4 1 V R R Line2 Interc2 In Out Interc POWER LINE 7 4 1 M 8 0 9 5 2 6 3 6 3 C 9 5 2 1 4 0 R 7 8 88888888 18 SIMPLE RESIDENTIAL INSTALLATION WITH PORTER S SWITCHBOARD Ref diagram...

Page 19: ...P L J1 D J1 DO J1 D J1 C D C D DO R R Line2 Interc2 In Out Interc POWER LINE 7 4 1 M 8 0 9 5 2 6 3 6 3 C 9 5 2 1 4 0 R 7 8 88888888 19 RESIDENTIAL VIDEO ENTRY INSTALLATION WITH ONE MAIN PANEL PORTER S...

Page 20: ...903 and con nect another relay to the R2 4 terminals of the power supply One or more extra alarm push buttons can also be fitted directly onto the distributor P1 P2 A A Digital distributor Art 949B Ph...

Page 21: ...Digital distributor Art 949B A VERSION 2B Monitor Art 6304 Art 6504 Art 6304 C Art 6324 Art 6324 C Art 6344 Art 6354 Relay Art 0170 001 Power supply Art 6948 Mains F1 additional function MONITOR CABLE...

Page 22: ...the switchboard Switchboard Art 945B BASIC DIAGRAM VERSIONS Relay Art 0170 001 External chime DIAGRAM SYMBOLS A C buzzer A C bell Electric lock Lamp Push button Switch Loudspeaker Amplified microphon...

Page 23: ...by sending specific commands on the digital signal which can now be verified via the switchboard or numerical entrance panel if fitted set to debug NOTES ON FUNCTIONS F1 F2 DOOR LOCK F6 F7 F8 1 Functi...

Page 24: ...ers If the crossed out bin symbol appears on the equipment or packaging this means the product must not be included with other general waste at the end of its working life The user must take the worn...

Reviews: