3
STORED CALLS
- Possibility of storing different types of "events": calls from interphones, activation of: different functions, door lock release,
calls from switchboard. The selection of the type of events to store is managed by interactive menu type display (see "OPE-
RATION OF MENU PROGRAMMING" ).
- Besides the type of message concerning the type of event and the calling number, the time of the event is stored.
- Maximum number of stored messages: 30 with circular queue (i.e. the latest 30 more recent events are stored).
- Storage of events on the watch backed up RAM (by means of a proper capacitor). In case of mains failure there is no loss
of stored data.
- The events may be sent to a printer simultaneously (option with interface type 945B/I).
- In case of events stored in the memory, a special flashing icon is activated (arrow toward the box
) on the display and
also the number of stored messages. As soon as a message is read it gets cancelled and the number decreases .
- A sound simultaneous with the event reception is generated (programmable).
INTERNAL WATCH WITH DATE AND TIME AND 2 WAKE UP SERVICES
It is always possible to display the present date and time. The internal watch is "backed up" (by means of a capacitor) in case
of mains failure (capacitor supply dwell: nearly 4 days). Two wake up services may be also programmed.
AUDIO EVENTS
Different types of sounds are forseen according to different type of events (call from riser, from external lines, wake up service
etc.). The sounds may be also programmed with musical melodies by means of a special software and an interface connec-
ted to a personal computer.
"SOFTWARE" LOCK KEY
The switchboard keypad may be locked by means of the "software key".
SIMPLIFIED MANAGEMENT OF THE "INTERNAL-EXTERNAL" MODE PUSH-BUTTON.
Now the "Internal-External" push-button (I/E) has only the function to switch from the internal to the external mode. In this new
version there is no keypad lock activation. At any time it is possible to recognize the switchboard state: a proper symbol on
the bottom on the right hand side of display (icon zone) indicates the mode ("I" for internal mode and "E" for external mode).
On external mode also the respective "EXTERNAL" mode LED switches on. NOTE: the state is memorized in EEPROM and is
kept stored even during the mains failure.
MANAGING THE PRINTER
-
The printer is connected by means a special optional interface, built-up inside the same switchboard.
-
Any printer provided with connected parallel circuit board may be installed (not any more a dedicated printer). It is the
internal software to manage the different models.
-
A wide range of data may be selected (either on reception either on transmission).
CIRCUIT BOARD RE-PROGRAMMING "IN-CIRCUIT".
The circuit board may be easily programmed "in-circuit" by proper connector (above all useful for special versions).
POSSIBLE CONNECTION TOWARD A PC
By means of a computer equipped with a proper software and interface it is possible to download the data (events in
memory), to manage the configuration parameters, to manage the names in memory (optional), and to set various functions.
Morover, it is possible to modify the musical melodies, the direct event recording, and to make a partial switchboard selfdia-
gnose.