9
EAM2, EAM3
IT
2x0.5 mm
2
2x1 mm
2
3x0.5 mm
2
4x0.5 mm
2
2x0.5 mm
2
2x2.5 mm
2
+3x0.5 mm
2
(encoder)
2x2.5 mm
2
+3x0.5 mm
2
(encoder)
3x1.5 mm
2
230/120 Vac
C
B
E
E
A
D
F
G
Key
A - Linear actuator
B - Control unit
C - Flashing light
D - 2-channel radio control
E - Pair of photocells
F - Selector
G - Electrical lock
1- Standard system setup
2- Technical data:
3- Dimensions and clearance of actuator EAM1 and EAM2:
Description
EAM2
EAM3
Electric motor power supply
24 Vdc
24 Vdc
Electric motor maximum absorption
5 A
5 A
Electric motor maximum power
120 W
120 W
Maximum gate leaf length
3 metres
4 metres
Maximum gate leaf weight
300 kg
250 kg
Maximum opening
110°
110°
Opening time
Min. 10sec. Max 22 sec.
Min. 15sec. Max 25 sec.
Protection rating
IP44
IP44
Operating temperature
From -20 to +55°C
From -20 to +55°C
Dimensions
785x110x105 mm
925x110x105 mm
Weight
9.2 kg
10.2 kg
Frequency of use
100%
100%
Useful travel
280 mm
430 mm
4- Limitations of use EAM2:
Limitations of use EAM3:
Length of gate leaf (metres)
Weight of gate leaf (kg)
2.5
550
3
400
3.5
300
4
250
Length of gate leaf (metres)
Weight of gate leaf (kg)
1.5
800
2
550
2.5
400
3
300
A
105 mm
110 mm
20 mm
EAM2 785 mm
EAM3 925 mm
18 mm