Due Fili Plus telephone interface

Wait for the three confirmation tones otherwise if you hear a brief tone and a long tone this means that programming 

has not been accepted.
At the end of the operations, proceed directly to a new programming or hang up the telephone.

5.14  Events (888 81 E M T PPP 1)

The 

controls

 can be managed automatically if and when certain events occur, such as ‘door open/closed’, ‘state of 

an actuator’ and entryphone call.
To associate an event E with the control M or with a group S, proceed as follows:

•  Call the internal tap-off or the telephone number of the indoor station where the interface is connected on a 

telephone, wait for the call tone and the subsequent brief tones (three repeated brief tones)

•  Type in code 

888

• Ty

pe in programming code 

81

• Ty

pe in the index of the event 

from 

to 

9

•  Type in the code of the control 

M

 from 

10 

to 

49

 you wish to associate.

•  Type in the code of the type of event 

T:

•  Type in the address 

PPP

 of the module associated with the event:

 

T

Event

Type

PPP

0

Door closed

Outdoor Station

001 … 015

1

Door open

Outdoor Station

001 … 015

2

Change of door state

Outdoor Station

001 … 015

3

Relay open state 

(only for appropriately configured 69PH)

Relay

001 … 016

4

Relay closed state 

(only for appropriately configured 69PH)

Relay

001 … 016

5

Change of relay state

Relay

001 … 016

6

Lock control

Outdoor Station

001 … 015

7

ATTEMPTED call from outdoor station

Outdoor Station

001 … 015

8

Call from outdoor station

Outdoor Station

001 … 015

•  Type in 

1

• Wai

t for the three confirmation tones otherwise if you hear a brief tone and a long tone this means that 

programming has not been accepted.

At the end of the operations, proceed directly to a new programming or hang up the telephone.

5.15  Delayed answer for entryphone calls (888 79 C T)

On arrival of an entryphone call, the interface may delay the answer, up to a maximum of 45 seconds, to give you the 

chance to answer from the entryphones present in the system. When the delay is up, the interface hooks up to the 

telephone line and transfers the entryphone call to the default number.

A different delay can be defined for each call button, between 0 and 45 seconds in 5-second

 steps (default 0 s).

To associate the call button C with the delay time T, proceed as follows:

•  Call the internal tap-off or the telephone number where the 40164 is connected on a telephone, wait for the call 

tone and the subsequent brief tones (three repeated brief tones)

•  Type in code 

888

• Ty

pe in programming code 

79.

• Ty

pe in the index referred to the call button 

(

from 1 to 4

) you wish to configure.

• Typ

e in the delay time 

from 

0

 to 

9

 (e.g. 1 = 5 s, 2= 10 s, etc.)

• Wai

t for the three confirmation tones otherwise if you hear a brief tone and a long tone this means that 

programming has not been accepted.

At the end of the operations, proceed directly to a new programming or hang up the telephone.

Summary of Contents for Elvox 40164

Page 1: ...Installer manual 40164 Telephone interface for Due Fili Plus entryphones and video entryphones...

Page 2: ...g a telephone call 888 62 SQ 7 5 6 Wait time before dialling a telephone number 888 85 T 7 5 7 Manual or automatic answer 888 75 C 1 0 7 5 8 Changing the interface address 888 74 C PPP 8 5 9 Master ad...

Page 3: ...ce can only be installed in a vertical Due Fili Plus BUS and it has the same installation restrictions as any Due Fili Plus indoor station It envisages three operating modes depending on the requireme...

Page 4: ...em and check it is working properly Secure 40164 to a DIN rail mounting frame Cut off the electricity power supply to the video door entry system Connect the Line terminals to an internal tap off N of...

Page 5: ...g programming simply recall the interface and resume programming from the last code executed 3 2 EXTENDED mode In this mode the IDs of the master devices must under all circumstances be programmed in...

Page 6: ...ce in the switchboard mode configuring it with ID 202 Should this ID already be occupied by a 40510 you will have to use different numbering the numbers possible on the Due Fili system are 201 202 203...

Page 7: ...the call tone and the subsequent three brief tones Type in the control code M followed by The default control codes are Code 11 Self start of master entrance panel Code 12 activates the master entran...

Page 8: ...ay with ID1 Control 4 activates the relay with ID2 Control 5 activates the relay with ID3 Control 6 activates the relay with ID4 Control 7 activates function F1 for the master entrance panel Control 8...

Page 9: ...wish to configure Wait for the three confirmation tones otherwise if you hear a brief tone and a long tone this means that programming has not been accepted At the end of the operations proceed direct...

Page 10: ...ed directly to a new programming or hang up the telephone The default interface occupies IDs from 41 to 80 in the Extended mode 888 87 C PPP If these IDs already exist in the system the default interf...

Page 11: ...g tone this means that programming has not been accepted At the end of the operations proceed directly to a new programming or hang up the telephone 5 11b Secondary telephone numbers 888 29 C I N In S...

Page 12: ...an entryphone communication or not Up to a maximum of 40 controls are envisaged associated with codes from 10 to 49 respectively The interface has the following default control configurations Code 11...

Page 13: ...ode 1 to activate 0 to deactivate Type in the index referred to the call button C from 1 to 4 Type in the confirmation code 5 Wait for the three confirmation tones otherwise if you hear a brief tone a...

Page 14: ...ock control Outdoor Station 001 015 7 ATTEMPTED call from outdoor station Outdoor Station 001 015 8 Call from outdoor station Outdoor Station 001 015 Type in 1 Wait for the three confirmation tones ot...

Page 15: ...ce or in the presence of echoes generally the more interference there is on the line the longer the minimum recognition duration To define the parameters of the telephone line proceed as follows Call...

Page 16: ...nd a long tone this means that programming has not been accepted At the end of the operations proceed directly to a new programming or hang up the telephone By default the interface is configured to m...

Page 17: ...Input voltage 24 48 VDC Maximum absorbed current Standby 38 mA Calling 50 mA Ring signal recognised 35Veff 25Hz 50Hz Busy tone recognition Frequency 425Hz 5Hz minimum tone duration 300ms DIGITAL BUS I...

Page 18: ...r waste The user must therefore hand the equipment at the end of its life cycle over to the appropriate municipal centres for the differentiated collection of electrical and electronic waste As an alt...

Page 19: ...17 Due Fili Plus telephone interface...

Page 20: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49401684A0_MI_IT 02 2107...

Reviews: