N
Parameter
Min.
Default Max
Note
21
Funct.1 activation time
1
1
255
F1 function activation duration in seconds (F1 line)
Check that the set times are compatible with the devices connected to
the corresponding outputs of the power supply.
22
Funct.2 activation time
1
1
255
F2 function activation duration in seconds (F2 line)
Check that the set times are compatible with the devices connected to
the corresponding outputs of the power supply
23
Lock activation time
1
1
255
Lock activation duration in seconds (SR line)
Check that the set times are compatible with the devices connected to
the corresponding outputs of the power supply.
24
Enab.Up Window
0
1
1
Enables the “initial user” - “final user” filter also for commands conveyed from
terminal 1 to terminal 6 of the entrance panel (0=No, 1=Yes).
25
Entrance panel backlight
LED Min Brightness (%)
5
25
100
Brightness of the backlight LEDs
26
Entrance panel backlight
LED Max Brightness (%)
50
75
100
Brightness of the backlight LEDs when the entrance panel is on.
27
Camera LED Brightness (%)
0
25
100
Brightness of the camera lighting LEDs
28
Seconds [0,59] (entrance
panel internal clock)
0
0
59
Seconds setting of the entrance panel internal clock.
29
Minutes [0,59] (entrance
panel internal clock)
0
0
59
Minutes setting of the entrance panel internal clock.
30
Hours [0,23] (entrance
panel internal clock)
0
0
23
Hours setting of the entrance panel internal clock.
31
Day of the month (entrance
panel internal clock)
1
1
31
Day of the month setting of the entrance panel internal calendar.
32
Month [1,12] (entrance
panel internal clock)
1
6
12
Month setting of the entrance panel internal calendar.
33
Year (entrance panel
internal clock)
2008
2008
2099
Year setting of the entrance panel internal calendar.
34
Day setting [0,6] (entrance
panel internal clock)
0
0
6
Day of the week setting of the entrance panel internal calendar.
0 = Sunday
35
Ext.1 Address
0
0
99999999
Address of external transponder reading device 1
36
Ext.2 Address
0
0
99999999
Address of external transponder reading device 2
37
Ext.3 Address
0
0
99999999
Address of external transponder reading device 3
38
Ext.4 Address
0
0
99999999
Address of external transponder reading device 4
39
Ext.5 Address
0
0
99999999
Address of external transponder reading device 5
40
Ext.6 Address
0
0
99999999
Address of external transponder reading device 6
41
Ext.7 Address
0
0
99999999
Address of external transponder reading device 7
42
Ext.8 Address
0
0
99999999
Address of external transponder reading device 8
43
Tx key
0
0
3
0 =
does not transmit the key;
1 =
transmits the key if it is in the entrance panel database
2 =
transmits the key if it is not in the entrance panel database
3 =
always transmits the key
44
Request Passw
0
0
1
1 =
requests password confirmation from the transponder reading device
45
Tx UP / Down
0
1
1
0 =
transmits the key on interphone cable riser serial line (UP)
1 =
transmits the key to the main entrance panel / switchboard (DOWN)
46
Hidden paras.
0
0
50
Typing 27 enables the display and programming of parameters 47 – 53
47
Mon. Off Time
0
30
1000
Monitor power-off timeout. The programmed value is multiplied by 10ms, the-
refore if Mon. Off Time = 30 then the timeout = 300ms
48
Transit Time
0
5
1000
Maximum transit time in minutes
49
Command Rep.(+)
0
388
65535
Repetition of special commands
50
Restart Tim.(h)
0
0
99999999
NOT USED
51
Factory reset
0
0
99999999
Typing the code 31830988 resets the parameters to their default values.
52
Flash sector reset
0
0
26
Erases the flash sector indicated from 1 to 26.
Important! Improper use of this parameter can damage the entrance
panel or cause malfunctions!
53
Number of keys from
keypad
0
0
0
(not used)
EN
18
1283 - 1285