POINT A - CONTROL PANEL FEATURES
J1
J15
J17
J2
J14
J4
J5
J3
J6
J9
J10
J11
J16
J7
J8
J13
J12
J1
L-N
230 Vac 50/60Hz power supply (120 Vac 60 Hz upon request)
J2
U - MOTOR
Motor common connection
V-W -
MOTOR
Motor phases and capacitor connections
Flashing light (max 40W )
J3
PROBE
- (not used)
J4
RADIO
Connector for radio module ACG8069
J5
RADIO
- (not used)
J6
Radio antenna
J7
- (not used)
J8
- (not used)
J9
APP+
- (not used)
J10 APP
- (not used)
J11 SERIAL COM
/SYNC
- (not used)
J12 R-AUX
Auxiliary relay contact (NO) Max 700 W
SIGN. -
Gate open state (12 Vdc 3 W max)
SIGN. +
J13 COM A+
Common contacts / Positive 24 Vdc
STOP
STOP impulse contact (NC)
PHOTO 1
Photocells contact 1 (NC)
PHOTO 2
Photocells contact 2 (NC)
EDGE
Edge contact (NC)
TLC
Vehicle presence signal (NO) (only when switched to PARK
mode)
J14 COM A+
Common contacts / Positive 24 Vdc
LSC
Closing limit switch contact (NC)
LSO
Opening limit switch contact (NC)
LSSC
Closing slowing down limit switch contact (NO)
LSSO
Opening slowing down limit switch contact (NO)
J15 COM A+
Common contacts / Positive 24 Vdc
OK CLOSE
Immediate closure command contact (only when switched to
PARK mode)
B.I.O.
Contact (NO) dedicated to a timer
START
Single pulse contact (NO)
CLOSE
Closing impulse contact (NO)
OPEN 2
Opening impulse contact (NO) - to exit (only in PARK mode)
OPEN 1
Opening impulse contact (NO) - to enter
J16 A+ COM
+ 24Vdc accessories power supply
A-
- 24Vdc accessories power supply
A+TEST
+ 24Vdc photocells self-test power supply
J17 CARD AUX
- (not used)
TCA
Trimmer for automatic closing time adjustment (DISABLED
DEFAULT AND DL11 LED OFF)
LOW SPEED
CLOSE
Electronic regulator for low speed on approach in closure
LOW SPEED
OPEN
Electronic regulator for low speed on approach in opening
PROG.
Programming button
F1 F T5A
Fuse for motor protection