34
9. Parameters table
Function
Parameters
Value range
Reso-
lution
Default value
Multi-function input
IN selection
[Off, Reduction,
Activation,
Heating/Air-Con.]
-
Off
Nighttime Reduction
δ
R
(red. offset)
[1,..,6]°C
0.1°C
4°C
Temperature control mode
Selection
TempCtrl
[Heat., Air-con.]
-
Heating
Control algorithm
Algorithm
[ON/OFF, PID]
-
ON/OFF
Hysteresis (ON/OFF)
δ
T
(Differential)
[0.1,..,1]°C
0.1°C
0.2°C
Proportional band (PID)
Band
[0.5,..,5]°C
0.1°C
1°C
Adjustment period (PID)
Period
[10,..,30] minutes
1 min
20 min
Unit of measurement (tem-
perature)
Temperature unit
[°C , °F]
-
°C
Temperature offset
T
E
(Offset temp.)
[0,..,±3]°C
0.1°C
0°C
Energy probe
Enable/Disable IN1
[ON, OFF]
-
ON
Enable/Disable IN2
[ON, OFF]
-
OFF
Enable/Disable IN3
[ON, OFF]
-
OFF
Calibration IN1
[0x000,..,0xFFF]
0x001
0x400
Calibration IN2
[0x000,..,0xFFF]
0x001
0x400
Calibration IN3
[0x000,..,0xFFF]
0x001
0x400
Enable/Disable Alarm
[ON, OFF]
-
ON
Alarm threshold
[3..10] kW
0.1 kW
4.2kW
Clock
Hours
[00,..,23]
1 h
00
Minutes
[00,..,59]
1 min
00
Day of the week
[Mon, Tue, Wed,
Thu, Fri, Sat, Sun]
-
-
Audible warnings
1
Enable audio feedback
[ON, OFF]
-
ON
PIN number
Pin
[000,..,999]
1
000
Reset to default parameters
rSEt
-
-
-