33
• Disconnection type: micro switch;
• PTI=175;
• Room temperature during transport: -25°C ÷ 60°C;
• Pollution level: 2;
• Software class: A;
• Nominal pulse voltage: 4000V;
• Clock error: ≤ 1s per day
14. Installation rules
Installation should be carried out by qualified personnel in compliance with the current regulations regarding
the installation of electrical equipment in the country where the products are installed.
15. Regulatory compliance
RED Directive.
Standards EN 60730-2-7, EN 60730-2-9, EN 301 489-17, EN 300 328, EN 62311.
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text of the EU
declaration of conformity is on the product sheet available at the following Internet address: www.vimar.com.
Installation rules - Regulatory compliance - Glossary
16. Glossary: names and meaning of network and WiFi parameters
WiFi
: name commonly used for wireless communication systems based on the IEEE 802.11 protocol. The
following characters (eg b/g/n) describe the type of modulation and/or the main frequency at which the wireless
device operates.
SSID
: WiFi network name (eg: “Home WiFi network”).
WPA/WPA2
: security systems for accessing a password-based WiFi network (recommended).
WEP
: security system for accessing an old type of WiFi network (not recommended: if you have a router with
this type of security system, you should modify it with WPA or WPA2). See paragraph 12, note 2.
IP
: communication protocol on which the entire Internet network is based.
IP Address
: the address that every device must have in order to communicate with other devices, via the IP
protocol. It consists of four numbers separated by periods (e.g.: 192.168.0.123).
Subnet mask
: (useful for devices that direct IP traffic) indicates the method of determining that a device
belongs to a subnet, that is its "class" (e.g.: 255.255.255.0 = class C).
DHCP
: method of automatically assigning IP addresses to devices. Typically the router in our home acts as
a "DHCP server", in other words it automatically assigns the IP address to all the devices connected to it.
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be included with other
general waste at the end of its working life. The user must take the worn product to a sorted waste center, or return it to the
retailer when purchasing a new one. Products for disposal can be consigned free of charge (without any new purchase obliga-
tion) to retailers with a sales area of at least 400 m
2
, if they measure less than 25 cm. An efficient sorted waste collection for the
environmentally friendly disposal of the used device, or its subsequent recycling, helps avoid the potential negative effects on the
environment and people’s health, and encourages the re-use and/or recycling of the construction materials.