1.4 Warranty
The equipment is covered by a 12-month parts-only warranty from the billing date.
The seller undertakes to replace all parts or equipment that it recognises as malfunctioning, to the exclu-
sion of any damages or penalties such as operating losses, market injury and other non-material or indirect
damage.
The following are excluded from our warranty: faults connected with abnormal use or use not in accord
-
ance with the recommendations in our manuals and instructions, defects found following normal wear and
tear, incidents caused by negligence, failure to monitor or maintain correctly, defects due to poor installa-
tion of the equipment or to poor storage conditions before installation.
In any event, the seller is not responsible for equipment that has been modified or repaired even if only
partially.
2. PRODUCT PRESENTATION
2.1 Description
The fire certificate number certifies that the JBRB ECOWATT
®
PR range complies with the order of 22
March 2004 of the French Interior Ministry.
400°C 1/2hr C4 APPROVED - Efectis certificate number: EFR-16-002341.
• Galvanised steel sheet casing equipped with 4 mounting feet (size 04 to 38) or 2 omega cross-piec-
es (sizes 48 to 92).
• High performance galvanised steel backward fan.
•
INTZ: installed/wired lockable safety switch.
•
ECM direct-current motor outside airflow:
-
04 to 22: IP44 class B single-phase 230V, 50Hz,
-
30, 38, 48, 70, 82: IP54, class F, single-phase 230V, 50Hz,
-
30, 38, 48, 70, 92: IP54, class F, three-phase 400V, 50Hz.
•
RMEC controller:
-
Constant pressure (COP), variable air volume (VAV), or constant air volume (CAV) operation.
-
Factory-installed and -wired IP55 controller..
-
Backlit LCD display, with front panel function buttons, optional remote control: clear displaying of measure
-
ment (pressure, air volume) and selected setting.
• Connection with circular bracket with class-D air duct seals. Vertical discharge version delivered with-
out connection bracket (optional PAPV sealed flat bracket for installation with self-drilling screws).
•
Standard or insulated version (M0 fire rating 25mm glass wool acoustic insulation).
• Cover equipped with handles, with tool-free removal.
• Horizontal or vertical discharge version.
•
3 available configurations: in-line, double inlet, modular: with elbow delivered with 1 stopper or 2 x
90° inlets.
Comment:
JBRB ECOWATT
®
PR models are equipped with an electronic-switching motor.
This motor is protected by:
- a built-in thermal protection on the motor winding,
- a thermistor built into the electronics.
These built-in motor protection systems have been tested and approved during fire-resistance testing and
certified C4 400°C 1/2hr.