ViM BATE-R010 Instruction Manual Download Page 2

 

2/8 NT00000592-BATE-R-010-AN-191114

CONTENTS

1. 

GENERAL INFORMATION ................................................................................................................ 2

1.1 Warnings .................................................................................................................................. 2
1.2 

Safety instructions  ................................................................................................................... 3

1.3 

Reception - Storage.................................................................................................................. 3

1.4 Warranty 

 .................................................................................................................................. 3

2. 

RANGE / PRODUCT PRESENTATION .............................................................................................. 3

3. INSTALLATION .................................................................................................................................. 4

3.1 Characteristics .......................................................................................................................... 4
3.2 Assembly .................................................................................................................................. 4

4. 

ELECTRICAL CONNECTION ............................................................................................................ 5

4.1 

BATE-R010 Single-phase - Power < 4kW ................................................................................ 5

4.2  BATE-R010 Single-phase - Power ≥ 4kW

 ................................................................................ 6

4.3 

BATE-R010 Three-phase - Power < 18kW ............................................................................... 6

4.4 

BATE-R010 Three-phase - Power 

 18kW............................................................................... 7

5. 

COMMISSIONING AND MAINTENANCE .......................................................................................... 7

5.1 

Normal operation ...................................................................................................................... 7

5.2 

Fault resolution  ........................................................................................................................ 8

5.3 Maintenance ............................................................................................................................. 8

6. 

WASTE MANAGEMENT .................................................................................................................... 8

6.1 

Treatment of packaging and General Industrial Waste (GIW) .................................................. 8

6.2 

Treatment of Professional WEEE ............................................................................................. 8

1. 

GENERAL INFORMATION

1.1  Warnings

This product has been manufactured in compliance with strict technical safety rules in accordance with EC 

standards, The EC declaration is downloadable from the website (details on final page),

Before installing and using this product, read these instructions carefully as they contain important infor-
mation for your safety and user safety, during installation, operation and maintenance of this product, Once 
installation is complete, ensure this manual is available for any later consultation,
The installation of this product and any other work (setup, connection, operation, maintenance) MUST be 
carried out by a professional following applicable best industry practice, standards and safety rules, It must 
comply with the requirements of the EMC and Low-Voltage Directives,

The manufacturer cannot be held liable for any injury and/or material damage caused by failure to comply 

with the safety instructions or due to any modification of the product,

BATE electrical heater are intended to be inserted into rigid galvanised steel or aluminium circular pipe 
systems for heating applications in tertiary buildings,

•  Installation inside premises
•  Speed in heater between 1,5m/s and 10m/s
•  Environmental temperature between -20°C / +50°C
•  Max, 95% relative humidity without condensation
•  Non-potentially-explosive atmosphere
•  Low-salinity atmosphere, without corrosive chemical agents

Summary of Contents for BATE-R010

Page 1: ...NSTRUCTION MANUAL INSTALLATION WIRING COMMISSIONING MAINTENANCE AFNOR CERTIFICATION ISO 14001 Environnement AFNOR CERTIFICATION ISO 9001 Q u a l i t BATE R010 Circular electrical heater with built in...

Page 2: ...instructions carefully as they contain important infor mation for your safety and user safety during installation operation and maintenance of this product Once installation is complete ensure this ma...

Page 3: ...ent is covered by a 12 month warranty Only parts from the date of invoice The seller undertakes to replace all parts or equipment that we recognise as malfunctioning to the exclu sion of any damages o...

Page 4: ...0 2 850 BATE R010 400 3 000W Single phase 3 000 13 0 9 1 276 376 470 50 0 680 4 600 BATE R010 400 5 000W Single phase 5 000 21 7 10 2 276 376 470 50 0 680 4 600 400V Three phase power supply BATE R010...

Page 5: ...equipped with two safety thermostats to avoid overheating An automatic reset safety thermostat 50 C and a manual reset safety thermostat 100 C located on the cover They must control an external contac...

Page 6: ...5 10 0 10VDC N L 230V 50Hz 4kW Equipment Included Optional BATE R010 Electrical heater MCR1 Post ventilation delay 4 3 BATE R010 Three phase Power 18kW 3 phases power supply airflow controller auto re...

Page 7: ...f the fan without the heater shutting off beforehand MCR1 type post ventilation delay if necessary or at the same time to be avoided Post ventilation block diagram BDEZ Safety thermostats fitted withi...

Page 8: ...tivated Once the error has been corrected press the man ual safety thermostat reset button on the electrical heater cover 5 3 Maintenance Regular inspection of connections Disassemble and clean the e...

Reviews: