LP/PROPANE Fixed Piping Connection
Connection:
Standard Residential 1/2” ID gas service line - 1/2” NPT male with 3/8” flare adapter.
Operating Pressure:
10.0” W.C.P. LP
Supply Pressure:
11” to 14” W.C.P. LP. If in excess of 14” W.C.P., a step-down regulator is required.
Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on
type and size of run and how deep to bury the lines. If the gas line is too small, the unit will not function properly.
To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 3/8” female flare adaptor to the
3/8” male flare adaptor to the regulator assembly. Ensure that the regulator arrow points in the direction of the gas flow
towards the unit and away from the supply. Connect the regulator assembly to the grill unit. Gas connectors must comply with
ANS Z21.75/ CSA 6.27. The maximum connection length shall be 6ft. The connection must be visible through a door or
opening in the enclosure. Piping, flex tubing, and connections within the built in enclosure shall be supported. Tubing and
connectors passing through openings within compartments in the built in enclosure shall be protected.
DO NOT forget to place the installer supplied gas valve in an accessible location.