Viking Professional VGSO100 Service Manual Download Page 11

© 2009 Viking Preferred Service 

11

Operation

®

natural airflow bake

OFF

BROIL

BAKE

CONVECTION

BAKE

CONVECTION

BROIL

convection bake

OFF

BROIL

BAKE

CONVECTION

BAKE

CONVECTION

BROIL

infrared broil

OFF

BROIL

BAKE

CONVECTION

BAKE

CONVECTION

BROIL

infrared convection broil

OFF

BROIL

BAKE

CONVECTION

BAKE

CONVECTION

BROIL

The 30” Single Wall Oven models offer the following cooking cycles:

 

Bake

(Natural Airflow Bake)

Full power heat is radiated from the U-shaped 
bake burners in the bottom of the oven cavity and 
is circulated with natural airflow. This function is 
recommended for single rack baking. Many cookbooks 
contain recipes to be cooked in the conventional 
manner. Conventional baking is suitable for dishes that 
require a high temperature. Use this setting for baking 
and preparing casserole dishes.

Convection Bake

Heat is radiated from the U-shaped bake burners 
in the bottom of the oven cavity. The heated air 
is circulated by one motorized fan in the rear of 
the oven providing a more even heat distribution. 
Multiple rack use is possible for the largest baking 
job. When roasting, cool air is quickly replaced—
searing meats on the outside and retaining more 
juices and natural flavor on the inside with less 
shrinkage. This even circulation of air equalizes 
the temperature throughout the oven cavity 
and eliminates the hot and cold spots found in 
conventional ovens.

Broil (Infrared Broil)

The broil burner at the top of the oven heats the 
metal screen until it glows. Heat radiates from 
the GourmetGlo™ infrared broiler located at the 
top of the oven cavity. The distance between the 
foods and the broil elements determines broiling 
speed. For “fast” broiling, food may be as close as 
2 inches (5 cm) to the broil element or on the top 
rack. “Fast” broiling is best for meats where rare to 
medium doneness is desired. Use this setting for 
broiling small and average cuts of meat.

Convection Broil

(Infrared Convection Broil)

The top element operates at full power. This 
function is exactly the same as regular broiling 
with the additional benefit of air circulation by 
the motorized fan in the rear of the oven. Smoke 
is reduced since the airflow also reduces peak 
temperatures on the food. Use this setting for 
broiling thick cuts of meats. 

Summary of Contents for Professional VGSO100

Page 1: ...uding but not limited to the following models VGSO100 30 Gas Single Wall Oven Service Manual This manual is to be used by qualified appliance technicians only Viking does not assume any responsibility...

Page 2: ...SHEETS BEFORE BEGINNING REPAIRS Pride and workmanship go into every product to provide our customers with quality appliances It is possible however that during the lifetime of a product service may b...

Page 3: ...rivate clubs churches etc This warranty excludes all commercial locations such as restaurants food service locations and institutional food service locations This warranty extends to the original purc...

Page 4: ...etain proof of original purchase to establish warranty period The return of the Owner Registration Card is not a condition of warranty coverage You should however return the Owner Registration Card so...

Page 5: ...ATION Oven Operation Main Panel 10 Bake Broil Convect Bake and Convect Broil 11 SERVICE DIAGNOSTICS AND PROCEDURES Service Situation Chart 12 Parts Location Control Panel 13 Parts Location Rear Oven 1...

Page 6: ...ounded 3 prong plug attached to product Flexible cord connector must be 1 2 ID 1 3 cm Cord must be agency approved for use with household gas ovens Maximum amp usage 8 0 amps Infrared broil burner rat...

Page 7: ...with natural or propane LP gas Before beginning installation verify that the model is compatible with the intended gas supply DANGER Fire explosion hazard IF THE INFORMATION IN THIS MANUAL IS NOT FOLL...

Page 8: ...be required U i Vi Li V iV i v i gas supply piping system during any pressure testing of that system Flexible Connections If the unit is to be installed with exible couplings and or quick disconnect t...

Page 9: ...ated on the top left side of the oven cavity under the control panel Model Numbers Serial Numbers The model and serial number tag is located on the inner frame to the lower left behind the door V G S...

Page 10: ...defrost foods OVEN LIGHT OVEN FUNCTION SET OVEN TEMPERATURE OFF 400 200 300 500 BROIL MIN SEC TIMER BAKE TIME START TIME CLOCK OFF BROIL BAKE CONV BAKE CONV BROIL Off On Indicator light Temperature Co...

Page 11: ...ultiple rack use is possible for the largest baking job When roasting cool air is quickly replaced searing meats on the outside and retaining more juices and natural avor on the inside with less shrin...

Page 12: ...X Inner Door Glass X Outer Door Glass X Door Hinge X Door Handle X Oven Racks X Oven Rack Supports X Oven RTD Temperature Sensor X Broil Burner X Broil Igniter X Bake Burner X Bake Igniter X Convecti...

Page 13: ...ocation Thermostat OVEN LIGHT OVEN FUNCTION SET OVEN TEMPERATURE OFF 400 200 300 500 BROIL OFF BROIL BAKE CONVECTION BAKE CONVECTION BROIL Main Control High Limit Thermostat 245 F N C Selector Switch...

Page 14: ...2009 Viking Preferred Service 14 Parts Location Rear Oven Pressure Regulator DSI Module Bake Solenoid Broil Solenoid Convection Motor 120VAC Power Cord Service Diagnostics and Procedures...

Page 15: ...Main Oven OVEN LIGHT OVEN FUNCTION SET OVEN TEMPERATURE OFF 400 200 300 500 BROIL OFF BROIL BAKE CONVECTION BAKE CONVECTION BROIL Bake Burner Bake Igniter Broil Igniter Broil Burner Service Plug Bake...

Page 16: ...pins in place close the door until pins stop door Lift the door up and then towards you The door will come off with the left and right locking pins holding the door hinges in place Place the door on...

Page 17: ...rature F Resistance approximate 50 1038 75 1090 100 1143 200 1350 300 1553 350 1654 400 1754 450 1852 500 1950 550 2047 600 2153 650 2238 700 2332 750 2425 800 2518 850 2609 900 2700 Component Reading...

Page 18: ...d Verify supply voltage No broil Bake igniter Bake solenoid Thermostat Selector switch DSI module Verify 120 VAC Verify 8 18 VDC Verify supply voltage Verify contacts closed Verify supply voltage No c...

Page 19: ...in range ohm each wire to ground If resistance is present then the RTD is grounded and the physical wires must be checked for a grounded connection If the RTD resistance is within range and the wires...

Page 20: ...is located on the right hand side by the cooling fan To access the limiter remove the oven from installation The main top will need to be removed and the limiter will be visible along the right hand s...

Page 21: ...120 VAC from terminals L1 double black wire to L2 neutral double white wire and should supply 120 VAC to P7 black of thermostat Electronic Thermostat The thermostat controls the temperature to the ov...

Page 22: ...SI Direct Spark Ignition module provides spark ignition for the oven burners When the oven receives an input from the end user the selector switch will send a signal to the DSI module for the appropri...

Page 23: ...from Selector BROIL J1 10 Black Line Voltage to DSI module Bake Mode 1 Set the Volt Ohm meter to read 120 VAC 2 Verify 120 VAC at module position 4 white and 10 black If no voltage is present verify...

Page 24: ...OT use voltage above 8 to 18 VDC to operate the solenoids To access the bake and broil solenoids remove the unit form installation and remove the rear cover The bake and broil solenoids are located on...

Page 25: ...2009 Viking Preferred Service 25 Wiring and Schematics...