22
Using a Viking Model RC-4A for Secure Remote Relay Control
Switch
SIP VoIP PBX,
SIP Cloud based
Service Provider
or
PC with SIP
Server Software
Internet
PoE
Switch
LED 8
LED 7
LED 6
LED 4
LED 3
LED 2
LED 1
LED 5
LED 9
1
2
3
on
4
1 2 3 4
VIKING
ELECTRONICS
HUDSON, WI 54016
NETWORK ENABLED
RELAY CONTROLLER
MODEL RC-4A
©
VIKING
1
IN1 C
IN2 IN3 C
IN4
2
3
4
5
6
POWER 12V DC
RELAY 1
RELAY 2
RELAY 3
RELAY 4
1
2
3
4
5
7
8
9 10 11 12
STATUS
LED
6
NETWORK
LOGIC LEVEL
PROGRAMMING
RESTORE DEFAULTS
SPARE
12V DC Adapter
(included)
Sensor
Examples:
Door Sensor
Gate Sensor
Door Sensor
Door Sensor
N.O.
COM.
Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
2 Gel-Filled Butt
Connectors
(included)
Doorstrike /
Magnetic Lock
120V AC
Door / Gate Examples:
Door near Entry Phone 1
N.O.
COM.
2 Gel-Filled Butt
Connectors
(included)
(Power typically not
required for gate controllers)
Gate Controller
K-1900-8-IP
Entry Phone 1
K-1900-8-IP
Entry Phone 4
Relay 2 Output Contacts
(5A@30VDC / 250VAC max)
Connect to Gate Controller, etc.
Gate near Entry Phone 1
N.O.
COM.
2 Gel-Filled Butt
Connectors
(included)
Doorstrike /
Magnetic Lock
120V AC
Door near Entry Phone 2
N.O.
COM.
Relay 4 Output Contacts
(5A@30VDC /
250VAC max)
Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
2 Gel-Filled Butt
Connectors
(included)
Doorstrike /
Magnetic Lock
120V AC
Door near Entry Phone 3
1
IN1 C IN2 IN3 C IN4
2 3 4 5 6
Relay 1 Output Contacts
(5A@30VDC / 250VAC max)
Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
Relay 3 Output Contacts
(5A@30VDC / 250VAC max)
K-1900-8-IP
Entry Phone 2
K-1900-8-IP
Entry Phone 3
The front panel of the
K-1900-8-IP Series
phone is mounted using security Torx screws to help prevent intruders from
removing the panel and accessing the on board door strike/gate control relays. For applications requiring additional security,
a Viking model
RC-4A
remote relay controller can be used. The relay controller is mounted securely inside the building and
connected to the same LAN as the
K-1900-8-IP Series
phone. The on board door strike relays would not be used in this
case as the
KK-1900-8-IP Series
phone will send an encrypted message to the
RC-4A
to activate its relays which control
the door strikes/gates.
Up to 4
K-1900-8-IP Series
phone’s can communicate with one
RC-4A
allowing you to securely control four entrances.
When using a
RC-4A
for remote relay control, the
K-1900-8-IP Series
phone’s relays should be set to “External” in the PC
programming.
For more information, see DOD 582 at www.VikingElectronics.com.