15
16. Relay 1 or 2 Internal / External
With relay 1 and/or 2 set to “Internal” the
K-1900-8-IP Series
phone will activate its on board relays for door strike /
gate control. Relay 1 and/or 2 should be set to “External” for higher security installations when using a Viking remote
model
RC-4A
relay controller to activate the door strike / gate controller (see page 22).
Note:
With relays set to external
the internal on board relays will also activate at the same time as the external relays.
Factory Setting:
Internal
Doorstrike Mode (Factory Setting):
When programmed for Doorstrike Mode the relay is intended for door strike,
maglock or gate control. The relay can also be touch tone activated by dialing a “#” plus a valid keyless entry code or
by scanning a valid proximity card that has been assigned to that relay.
Outbound Call Mode:
When programmed for Outbound Call Mode the relay will activate continuously for the duration
of any outbound call from the Entry phone.
Inbound/Outbound Call Mode:
When programmed for Inbound/Outbound Call Mode the relay will activate
continuously for the duration of any inbound or outbound call to or from the Entry phone. This mode is useful for turning
on IR flood lights, for VoIP phones with cameras, etc.
Doorbell Mode:
When programmed for Doorbell Mode the relay will momentarily activate the relay for the
preprogrammed relay activation time on any outbound call from the Entry phone. This mode is useful for activating a
door chime, etc. When activating door chimes, a 0.5 - 1 second relay activation time is recommended.
Alarm Mode:
When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered
and registered to the SIP server. In the event the unit loses power and/or SIP registration the relay will turn off, which
can be used to signal an alarm device. This can only be used for internal relay control.
Ring Mode:
When programmed for Ring Mode the relay will continuously activate while the ringing extension is called.
This mode is useful for activating a Viking model
SL-2
strobe light, etc.
Ring Flash Mode:
When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400ms
on/off cadence while the ringing extension is called. This mode is useful for activating a Viking
LPL-1
Remote Visual
Indicator, etc.
17. Relay Mode