Viking K-1275-IP Series Product Manual Download Page 7

7

Using a Viking Model RC-4A for Secure Remote Relay Control

Switch

SIP VoIP PBX, 

SIP Cloud based 
Service Provider

or

PC with SIP 

Server Software

Internet

PoE

Switch

LED 8

LED 7

LED 6

LED 4

LED 3

LED 2

LED 1

LED 5

LED 9

1

2

3

on

4

1 2 3 4

VIKING

ELECTRONICS

HUDSON, WI 54016

NETWORK ENABLED

RELAY CONTROLLER

MODEL RC-4A

©

VIKING

1

IN1  C

IN2 IN3  C

IN4

2

3

4

5

6

POWER 12V DC

RELAY 1

RELAY 2

RELAY 3

RELAY 4

1

2

3

4

5

7

8

9 10 11 12

STATUS

LED

6

NETWORK

LOGIC LEVEL
PROGRAMMING
RESTORE DEFAULTS
SPARE

12V DC Adapter

(included)

Sensor

Examples:

Door Sensor

Gate Sensor

Door Sensor

Door Sensor

N.O.

COM. 

Connect to Doorstrike,

Mag Lock, Gate Controller, etc.

2 Gel-Filled Butt

Connectors 

(included)

Doorstrike / 
Magnetic Lock

120V AC

Door / Gate Examples:

Door near Entry Phone 1

N.O. 

COM. 

2 Gel-Filled Butt

Connectors 

(included)

(Power typically not

required for gate controllers)

Gate Controller

K-1275-IP

Entry Phone 1

K-1275-IP

Entry Phone 2

K-1275-IP

Entry Phone 3

K-1275-IP

Entry Phone 4

 Relay 2 Output Contacts 

(5A@30VDC / 250VAC max)

Connect to Gate Controller, etc.

Gate near Entry Phone 1

N.O.

COM. 

2 Gel-Filled Butt

Connectors 

(included)

Doorstrike / 
Magnetic Lock

120V AC

Door near Entry Phone 2

N.O.

COM. 

 Relay 4 Output Contacts 

(5A@30VDC / 

250VAC max) 

Connect to Doorstrike, 

Mag Lock, Gate Controller, etc.

2 Gel-Filled Butt

Connectors 

(included)

Doorstrike / 

Magnetic Lock

120V AC

Door near Entry Phone 3

1

IN1  C IN2 IN3  C IN4

2 3 4 5 6

 Relay 1 Output Contacts 

(5A@30VDC / 250VAC max)

Connect to Doorstrike,

Mag Lock, Gate Controller, etc.

 Relay 3 Output Contacts 

(5A@30VDC / 250VAC max)

The front panel of the 

K-1275-IP

is mounted using security Torx screws to help prevent intruders from removing the panel

and accessing the on board door strike/gate control relays. For applications requiring additional security, a Viking model

RC-4A

remote relay controller can be used. The relay controller is mounted securely inside the building and connected to

the same LAN as the 

K-1275-IP

.  The on board door strike relays would not be used in this case as the 

K-1275-IP

will send

an encrypted message to the 

RC-4A

to activate its relays which control the door strikes/gates. For more information, see

DOD# 582 at www.VikingElectronics.com.

Up to 4 

K-1275-IP’s

can communicate with one 

RC-4A

allowing you to securely control four entrances.

When using an 

RC-4A

for remote relay control the 

K-1275-IP’s

relays should be set to “External” in the PC programming.

Note: 

If the 

K-1275-IP

loses communications with the 

RC-4A

, the LED on the front panel of the 

K-1275-IP

will flash 3 times

every 2 seconds indicating the communication error. If this error occurs, make sure the 

RC-4A

is powered, has a network

connection and has the correct IP address and security code of the 

K-1275-IP

displaying errors.

Summary of Contents for K-1275-IP Series

Page 1: ...er or business extension When the K 1275 IP phone is connected to an apartment or business tenant a built in contact closure may be activated to control an electric gate or door strike Up to 1 000 key...

Page 2: ...em or Service Provider Ring Central Requires Authorization ID and Proxy address Vendor Infrastructure Class Softswitch PBX Proxy SBC session border controller Service Provider 3COM VCX X 3CX X Aastra...

Page 3: ...t forwards data from one network to another In order to send information to the right location routers look at IP Address MAC Address and Subnet Mask RTP Real Time Transport Protocol is an Internet pr...

Page 4: ...r insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Keypad Push to initiate call push again to disconnect Zinc Die cast with Satin Chrome Finish internally sealed p...

Page 5: ...using the included rough in box or as a surface mount unit using an optional VE 5x10 or VE 5x10 SS The rough in box uses the inner set of four holes on the face plate while the VE 5x10 uses the outsi...

Page 6: ...ndustrial St Hudson WI 54016 DEV RoHS J6 J6 MAC 18E80FXXXXXX asdesaxtff Note Up to 150 ft video cable run length can be achieved using CAT5E or CAT6 cable Longer cable runs can be used if a passive or...

Page 7: ...ller etc 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrik...

Page 8: ...582 Extends range of cable keeps 1 Gbps network speed for other equipment on network SIP VoIP PBX or PC with SIP Server Software Viking K 1275 IP Entry Phone 10 100 Mbps Maximum Optional Switch Hub Op...

Page 9: ...lure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the network will appear on the list...

Page 10: ...for the K 1275 IP in the Unit Name field When finished click on the Apply button to send the IP settings to the connected unit See Examples 1 and 2 of the required fields below Step 1 Power down the K...

Page 11: ...or 2 Command 1 or 2 digits factory set to QQ and Q2 Relay Mode must be set to Door Strike 18 16 Relay 1 or 2 Time 0 5 99 sec factory set to 5 sec 19 16 Relay 1 or 2 Int Ext factory set to Internal 20...

Page 12: ...re not uploaded The Index Number is the single digit number visitors enter on the K 1275 IP s keypad for the unit to call the tenant 3 seconds after the number is entered the unit will then dial the P...

Page 13: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Page 14: ...ame can be assigned to the K 1275 IP being programmed Often times the building name and entrance location near the unit are used for the name A network failure alarm will be indicated by providing 3 b...

Page 15: ...should be heard You can now enter any Remote Access Operation Commands see page 19 12 Access Code The Inbound Call Mode determines how the K 1275 IP handles incoming calls The K 1275 IP can auto answe...

Page 16: ...ghts for VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activate the relay for the preprogrammed relay activation time on any outbound call fro...

Page 17: ...ne buzz can be programmed to three different volume settings 1 Low 2 Medium 3 High or it can be disabled 22 Relay Buzz Activation Tone Volume The speaker volume can be set from 0 to 9 0 lowest volume...

Page 18: ...for the programmed Relay 2 Activation Time If Relay Activation Delay is not disabled Relay 2 will be activated for the programmed Relay 2 Activation Time then after the Relay Activation Delay time ha...

Page 19: ...obs can also be used by the tenants to provide keyless entry The K 1275 IP can be programmed with up to 1000 proximity card numbers Each proximity card number can be programmed to activate relay 1 and...

Page 20: ...th a blank aluminum panel The user can customize the clear coated aluminum panel to mount an PRX 1 card reader PRX 2 keypad or switch The kits come complete with box gasket panel and screws Model numb...

Page 21: ...so be used as a close range access credential The transmitters and receivers operate at 433 MHz allowing a transmission range of up to 400 ft line of sight The LRR 4 receiver has an adjustable read ra...

Page 22: ...o a PO Box 4 RA number on carton In large printing write the R A number on the outside of each carton being returned RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that has fa...

Reviews: