Features Overview

MAC:

18E80FXXXXXX

asdesaxtff

N.C.

 - Black

+ Red

 - Black

+ Red

 Green

 Green

 Green

 White

N.O.

COM.

N.C. (Gray)

N.O. (Yellow)

COM. (Blue)

 Relay 1

Output Contacts

(2A@30VDC/ 250VAC max)

 Relay  2 Output Contacts

(2A@30VDC/ 250VAC max)

 Request for Exit 

(REX) Input

3 Gel-Filled Butt

Connectors 

(included)

+ Red

- Black

Black

Black

- Black

+ Red

Speaker

LED

Microphone

Call Switch

MAC Address Label: 

The 

MAC address is aunique 
12 digit number used by 
routers to send network 
traffic to the correct IP 
address.

PoE LAN Port 10/100, 
PoE Class 2 (<6.5 Watts): 

Connect to your LAN via 
RJ45 plug and CAT5 or 
greater twisted pair wire.

Yellow Network Status 
LED: 

Lights steady to 

indicate power and data 
link. Blinks to indicate 
network activity.

Green Unit Status LED

Rear (PCB) View of K-1275-IP

White

White

(Power typically not

required for gate controllers)

Doorstrike / 
Magnetic Lock

120V AC

Connect to Optional 

Doorstrike, Mag Lock, 

Gate Controller, etc.

(not

connected)

Proximity Card 

Reader (26 Bit 

Wiegand Input)

12 VDC Power Output for 

VE-LIGHT, etc. 

(12VDC @ 50mA max)

  

Camera

Power  

 - Black

+ Red

Brown

Violet

White

Optional: Connect to an additional 
Long Range RFID Receiver with 26 
Bit Wiegand Output (Viking Model 
PRX-3 or LRR-4 See DOD# 228 or 
226)

 Optional

Long Range 

RFID Receiver 

Note:  

The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches. 

Keypad:

  Push to initiate call, push again to 

disconnect. Zinc Die cast with Satin Chrome 
Finish, internally sealed per IP67.

Speaker Screen:

  Speaker screen with 0.018" 

wide slots to prevent punctures from paperclips, 
etc.

Faceplate Material:

  14 gauge 316 stainless steel 

with #4 brushed finish.

Speaker:

  Mylar speaker with rubber gasket to 

maintain water-tight seal and eliminate water 
deterioration.

Blue Call LED:

  Lights steady when idle, flashes 

during dialing, then lights steady when answered.

Microphone:

  Omni-directional microphone with 

protective water-resistant cloth.

Front View of the

K-1275-IP Entry Phone

Condensation Drain Hole

Mounting Screws:

    (4) 6-32 X 3/4” Marine grade 

316 stainless steel, flat head, T-10 Torx security 
screws and drive bit (included).

Laser Etched Graphics: 

For long lasting easy to 

read graphics. 

VIKING

©

1

2

3

4

5

6

7

8

9

0

  

#

*

#

*

   

0

9

8

7

6

5

4

3

2

1

1

2

3

4

5

6

7

8

9

0

#

*

Color Video Camera:

  Wide operating 

temperature range of -40°F to 140°F, NTSC 
composite video output with 420 lines of 
resolution, 80° wide viewing angle lens, tilt and 
swivel adjustments for aiming towards visitors.

Protective Camera Window:

  Impact resistant 

polycarbonate lens with scratch resistant 
coating and water-tight gasket.

Proximity Card Reader:

  26-bit Wiegand, 

125KHz, red LED turns off and transducer will 
beep during card read. Fully potted EWP. Read 
range 1.25" to 2.0". Impact resistant 
polycarbonate lens with water-tight gasket.

Summary of Contents for K-1275-IP Series

Page 1: ...er or business extension When the K 1275 IP phone is connected to an apartment or business tenant a built in contact closure may be activated to control an electric gate or door strike Up to 1 000 key...

Page 2: ...em or Service Provider Ring Central Requires Authorization ID and Proxy address Vendor Infrastructure Class Softswitch PBX Proxy SBC session border controller Service Provider 3COM VCX X 3CX X Aastra...

Page 3: ...t forwards data from one network to another In order to send information to the right location routers look at IP Address MAC Address and Subnet Mask RTP Real Time Transport Protocol is an Internet pr...

Page 4: ...r insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Keypad Push to initiate call push again to disconnect Zinc Die cast with Satin Chrome Finish internally sealed p...

Page 5: ...using the included rough in box or as a surface mount unit using an optional VE 5x10 or VE 5x10 SS The rough in box uses the inner set of four holes on the face plate while the VE 5x10 uses the outsi...

Page 6: ...ndustrial St Hudson WI 54016 DEV RoHS J6 J6 MAC 18E80FXXXXXX asdesaxtff Note Up to 150 ft video cable run length can be achieved using CAT5E or CAT6 cable Longer cable runs can be used if a passive or...

Page 7: ...ller etc 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrik...

Page 8: ...582 Extends range of cable keeps 1 Gbps network speed for other equipment on network SIP VoIP PBX or PC with SIP Server Software Viking K 1275 IP Entry Phone 10 100 Mbps Maximum Optional Switch Hub Op...

Page 9: ...lure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the network will appear on the list...

Page 10: ...for the K 1275 IP in the Unit Name field When finished click on the Apply button to send the IP settings to the connected unit See Examples 1 and 2 of the required fields below Step 1 Power down the K...

Page 11: ...or 2 Command 1 or 2 digits factory set to QQ and Q2 Relay Mode must be set to Door Strike 18 16 Relay 1 or 2 Time 0 5 99 sec factory set to 5 sec 19 16 Relay 1 or 2 Int Ext factory set to Internal 20...

Page 12: ...re not uploaded The Index Number is the single digit number visitors enter on the K 1275 IP s keypad for the unit to call the tenant 3 seconds after the number is entered the unit will then dial the P...

Page 13: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Page 14: ...ame can be assigned to the K 1275 IP being programmed Often times the building name and entrance location near the unit are used for the name A network failure alarm will be indicated by providing 3 b...

Page 15: ...should be heard You can now enter any Remote Access Operation Commands see page 19 12 Access Code The Inbound Call Mode determines how the K 1275 IP handles incoming calls The K 1275 IP can auto answe...

Page 16: ...ghts for VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activate the relay for the preprogrammed relay activation time on any outbound call fro...

Page 17: ...ne buzz can be programmed to three different volume settings 1 Low 2 Medium 3 High or it can be disabled 22 Relay Buzz Activation Tone Volume The speaker volume can be set from 0 to 9 0 lowest volume...

Page 18: ...for the programmed Relay 2 Activation Time If Relay Activation Delay is not disabled Relay 2 will be activated for the programmed Relay 2 Activation Time then after the Relay Activation Delay time ha...

Page 19: ...obs can also be used by the tenants to provide keyless entry The K 1275 IP can be programmed with up to 1000 proximity card numbers Each proximity card number can be programmed to activate relay 1 and...

Page 20: ...th a blank aluminum panel The user can customize the clear coated aluminum panel to mount an PRX 1 card reader PRX 2 keypad or switch The kits come complete with box gasket panel and screws Model numb...

Page 21: ...so be used as a close range access credential The transmitters and receivers operate at 433 MHz allowing a transmission range of up to 400 ft line of sight The LRR 4 receiver has an adjustable read ra...

Page 22: ...o a PO Box 4 RA number on carton In large printing write the R A number on the outside of each carton being returned RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that has fa...

Reviews: