16
The Daylight Savings Time programming can be enabled or disabled and can be programmed to start on any Sunday in March and
stopped on any Sunday in November. Currently, daylight saving time starts on the second Sunday in March and ends on the first
Sunday in November, with the time changes taking place at 2:00AM local time.
15. Daylight Savings
Keyless Entry Code and Proximity Card logging can be set to Log Errors. With Log Errors selected (default selection), the
K-1275-
IP
will not only log all valid Keyless Entry Code and Proximity Card entries, but also log any errors, incorrect codes, or non-valid card
reads.
Keyless Entry Code and Proximity Card logging can also be set to Live Logging. With Live logging selected and the
K-1275-IP
programming software open and connected to a unit, each Keyless Entry Code entered or Proximity Card read will immediately open
the Event Log screen and display the latest entry.
16. Keyless/Card Logging
When using date and time logged events or setting the access date and times of keyless codes or proximity cards in the Entry Code
Database, you must program the unit to your time zone. Example: You are installing the
K-1275-IP
in the Central standard time zone:
Select (UTC - 06:00) CST, which is 6 hours behind Coordinated Universal Time (UTC).
14. Select Time Zone
Doorstrike Mode:
When programmed for Doorstrike Mode the relay is intended for door strike, maglock or gate control. The relay
can also be touch tone activated by dialing a “#” plus a valid keyless entry code or by scanning a valid proximity card that has been
assigned to that relay.
Outbound Call Mode:
When programmed for Outbound Call Mode the relay will activate continuously for the duration of any
outbound call from the Entry phone.
Inbound/Outbound Call Mode:
When programmed for Inbound/Outbound Call Mode the relay will activate continuously for the
duration of any inbound or outbound call to or from the Entry phone. This mode is useful for turning on IR flood lights, for VoIP phones
with cameras, etc.
Doorbell Mode:
When programmed for Doorbell Mode the relay will momentarily activate the relay for the preprogrammed relay
activation time on any outbound call from the Entry phone. This mode is useful for activating a door chime, etc. When activating door
chimes, a 0.5 - 1 second relay activation time is recommended.
Alarm Mode:
When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered and registered
to the SIP server. In the event the unit loses power and/or SIP registration the relay will turn off, which can be used to signal an alarm
device. This can only be used for internal relay control.
17. Relay Mode
The one or two digit code stored in the Relay Activation Command is the touch tone command that the person being called must
enter on their phone in order to momentarily activate relay 1 or 2 to control a doorstrike, mag-lock, gate controller, or other device.
The code can contain the characters 0 - 9, # or
Q
. The code cannot match a relay latching or toggle command (11, 10, 1#, 21, 20,
or 2#). The code must be entered while the remote phone is communicating with the Entry phone. The Entry phone determines which
direction the touch tone is coming from and only responds to touch tones from the called phone. The factory setting is
for relay
1 and
Q
2 for relay 2. Both relays can be controlled by the same activation command.
18. Relay 1 or 2 (Activation) Command
The value stored in the Relay 1 or 2 Activation Time is the amount of time relay 1 or 2 will be energized after a correct momentary
touch tone command is entered, “#” plus a valid keyless entry code or a proximity card was scanned that is programmed to
momentarily activate the relay. This number can range from 0.5 to 99 seconds. The factory setting is 5 seconds.
19. Relay 1 or 2 Activation Time
20. Relay 1 or 2 Internal / External
With relay 1 and/or 2 set to “Internal” the
K-1275-IP
will activate its on board relays for door strike / gate control. Relay 1 and/or 2
should be set to “External” for higher security installations when using a Viking remote model
RC-4A
relay controller to activate the
door strike / gate controller (see page 6).