background image

3

2

Warnings & Important Safety Instructions ______________________________________________________________________3
Dimensions (Professional)____________________________________________________________________________________5
Dimensions (Custom Panel) __________________________________________________________________________________6
Specifications ______________________________________________________________________________________________7
Cutout Dimensions _________________________________________________________________________________________7
Drain/Electrical Locations ____________________________________________________________________________________8
General Information ________________________________________________________________________________________9
Air Flow ___________________________________________________________________________________________________9
Filters and Treatment _______________________________________________________________________________________9
Installation Overview_______________________________________________________________________________________10
Accessory Door Panel ______________________________________________________________________________________10
Custom Panel _____________________________________________________________________________________________10
Door Panel Attachment ____________________________________________________________________________________12
Door Swing Change _______________________________________________________________________________________13
Water and Drain Installation ________________________________________________________________________________14
Electrical Connection ______________________________________________________________________________________16
Final Installation ___________________________________________________________________________________________16
Installation Checklist _______________________________________________________________________________________16
Service Information ________________________________________________________________________________________17

•  Before beginning, please read these instructions completely and carefully.
•  DO NOT remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.
•  Please observe all local and national codes and ordinances.
•  Please ensure that this product is properly grounded.
•                     The installer should leave these instructions with the consumer who should retain for local inspector’s use and for

future reference.

A GFI 

shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances.

• The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of

water or moisture.

• Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not

meet the requirements below.

If the use of a GFI is required

, it should be:

• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible

It is your responsibility to be sure your ice machine is:
• located so the front is not blocked to restrict incoming or discharge air flow.
• properly leveled.
• located in a well ventilated area. 
• connected to the proper kind of outlet, with the correct electric supply and grounding. A 115V, 60 Hz, 15 amp fused

electrical supply is required. 

Note: Time delay fuse or circuit breaker is recommended.

• not used by anyone unable to operate it properly.
• used only for its intended purpose.
• properly maintained.

•SAVE THESE INSTRUCTIONS•

WARNING

To reduce the risk of fire, electric shock, or injury when using your unit, follow these basic precautions:

• Read all instructions before using the unit.
• Never allow children to operate, play with, or crawl inside the unit.
• Never clean unit parts with flammable fluids. The fumes can create a fire hazard or explosion.
• Always turn the power on/off switch (located behind the air grille on top right side) to the OFF

position before attempting to change light bulbs, clean, or service the unit.

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE. THE FUMES CAN CREATE A FIRE HAZARD OR
EXPLOSION.

Table of Contents

Important - Please read and Follow!

Summary of Contents for FGNI515

Page 1: ...ront Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our web site at vikingrange com in the US or brigade ca in Canada UL C UL Installation Guide 15 W Undercounter Freestanding Nugget Ice Machine ...

Page 2: ...nty Please observe all local and national codes and ordinances Please ensure that this product is properly grounded The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference A GFI shall be used if required by NFPA 70 National Electric Code federal state local laws or local ordinances The required use of a GFI is normally re...

Page 3: ...ance in a way that minimizes the possibility that children will find it There have been many cases in years past of children crawling inside junked and abandoned refrigeration units and becoming trapped or suffocated Contact your municipal waste disposal authority to find out the best and safest way to dispose of your old refrigeration unit 14 3 4 37 5 cm 3 7 8 9 8 cm Floor drain access hole 90 0 ...

Page 4: ...5 9 cm 22 3 4 57 8 cm 25 1 4 64 1 cm Cutout width 15 38 1 cm Cutout height 34 1 4 86 4 cm min to 35 1 4 89 5 cm max Cutout depth 24 61 0 cm Electrical requirements 115V 60 Hz 15 amp dedicated circuit 6 3 wire cord attached to product Maximum amp usage 5 0 amps Inlet water requirement 1 4 OD copper tubing inlet waterline 20 psi min to 80 psi max 50 F 10 C min to 100 F 38 C max Drain requirements 5 ...

Page 5: ...plied with ice machine 1 Remove the gasket and retain for later use 2 If the door panel is stainless steel remove any plastic covering the stainless steel panel 3 Place the panel onto the outside of the door and secure it to the door using two machine screws located at the left center and right center behind door gasket 4 Fasten the panel to the door using the 6 screws supplied with door panel In ...

Page 6: ...op of door and bottom of countertop edge from cabinet opening This is the maximum door length 5 Cut panel to width 6 Cut panel to length cabinet space kickplate space top clearance length 7 Determine top of panel 8 Mark hole locations using drawing on the back of these instructions Drawing assumes top of panel will be flush with top of door Measure hole locations from the top of the panel 9 Drill ...

Page 7: ...at insert a stop into the provided hole in the top and bottom hinges Drive the pin into the hole until the head is against the hinge HINGE COVERS After the hinge pins are installed if used and the door panel has been attached attach the hinge covers 1 Slide the hinge cover over each hinge 2 Attach the side cover over the hinge by peeling off the covering over the adhesive and placing it over the s...

Page 8: ...ION Restrictions in the drain system to the machine will cause water to back up into the ice storage bin and melt the ice Gravity drain tubing must be vented have no kinks and slope to the building drain Air gaps are typically required by local code WATER DRAIN INSTALLATION The recommended water supply tubing is 1 4 OD copper Stainless steel flex or reinforced PVC tube may also be used Install an ...

Page 9: ...REFERENCE Model and Serial number The ice machine is supplied with a power cord DO NOT remove the grounding pin from the cord s plug DO NOT use extension cords Follow all codes Connect the machine to its own 115 volt 15 amp circuit FINAL INSTALLATION 1 If the electrical outlet for the ice maker is behind the unit plug in the unit 2 Snap the black caps over the bottom of the leveling legs 3 Positio...

Page 10: ...19 18 ...