Electrical & Gas Requirements

10

Electrical Requirements

Check your national and local codes
regarding this unit. This range requires
120VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord
with grounded 3-prong plug attached to
unit. See “Electrical Connection” section for
grounding instructions. Must be fused
seperately from any other circuit.

Gas Connection

The gas supply (service) line must be the
same size or greater than the inlet line of the
appliance. This range uses a 1/2” (1.3 cm) ID
NPT (Sch40) inlet. Sealant on all pipe joints
must be resistive to LP gas.

The range is designed specifically for
natural gas or liquid propane (LP) gas.
Before beginning installation verify that
the model is compatible with the intended
gas supply.

Manual shut-off valve:

This installer-supplied valve must be installed
in the gas service line before the appliance
in the gas stream and in a location where it
can be reached quickly in the event of
an emergency. Any opeing behind the range
shall be sealed.

In Massachusetts:

A “T” handle type

manual valve must be installed in the gas
supply line to the appliance.

IMPORTANT: Any conversion required
must be performed by your dealer or a
qualified licensed plumber or gas service
company

. Please provide the service person

with this manual before work begins.

Pressure Regulator:

• All heavy-duty, commercial type cooking

equipment must have a pressure regulator
on the incoming service line for safe and
efficient operation, since service pressure
may fluctuate with local demand. External
regulators are not required on this range
since a regulator is built into each unit at
the factory. Under no condition bypass
this built-in regulator.

• Manifold pressure should be checked with

a manometer, natural gas requires 5.0”
W.C.P. and LP gas requires 10.0” W.C.P.
Incoming line pressure upstream from the
regulator must be 1” W.C.P. higher than
the manifold pressure in order to check
the regulator. The regulator used on this
range can withstand a maximum input
pressure of 1/2” PSI (14.0” W.C.P.). If the
line pressure is in excess of that amount, a
step down regulator will be required.

• The appliance must be disconnected from

the gas supply piping system during any
pressure testing of that system.

2”

dia.

(5.1 cm)

 

2-3/4”

(7.0 cm)

2-1/2”

(6.4 cm)

1-3/4”

(4.4 cm)

28-5/16”

(71.9 cm)

23-7/16”

(59.5 cm)

Gas or electrical
connection in
this area

Gas connection 
in this area

4-3/8”

(11.1 cm)

31-1/16”

(78.9 cm)

WARNING

ELECTRICAL SHOCK

HAZARD

To avoid the risk of electrical

shock, personal injury or death;

verify electrical power is turned off at the

breaker box and gas supply is turned off

until the range is installed and ready to

operate, installation by an authorized

installer only.

Flexible Connections:

If the unit is to be installed with flexible
couplings and/or quick-disconnect fittings,
the installer must use a heavy-duty AGA
design-certified flexible connector of at least
1/2” (1.3 cm) ID NPT (with suitable strain
reliefs) in compliance with ANSI Z21.41
and Z21.69.

In Canada:

CAN 1-6, 10-88 metal

connectors for gas appliances and CAN
1-6.9 M79 quick disconnect devices for use
with gas fuel.

In Massachusetts:

This appliance must be

installed with a 36” (3-foot) long flexible
gas connector.

Electrical & Gas Requirements

Summary of Contents for F20513

Page 1: ...Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20513A EN 070208J Viking Installation Guide Professional Freesta...

Page 2: ...property damage All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed WARNING CAUTION Warnings Impo...

Page 3: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qua...

Page 4: ...depth Overall 18 3 4 47 6 cm AHAM VGCC530 17 43 1 cm AHAM VGSC530 15 3 8 39 0 cm Oven volume Total oven capacity 4 0 cu ft Measured to AHAM standards VGCC530 3 7 cu ft Measured to AHAM standards VGSC...

Page 5: ...be 30 76 2 cm min to 36 91 4 cm max above the countertop This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the range hood installation ins...

Page 6: ...al regulators are not required on this range since a regulator is built into each unit at the factory Under no condition bypass this built in regulator Manifold pressure should be checked with a manom...

Page 7: ...Installation section Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film residues and a...

Page 8: ...l mounting hardware 3 Screw legs into couplings on all four corners Leg Installation 1 2 Measure the four corners in cutout area to verify if flooring is level For uneven or sloped floors level unit w...

Page 9: ...ration always check for gas leaks This must be performed by your dealer a qualified licensed plumber or gas service company Leveling Adjustments Alignments cont Connecting Gas Electric WARNING TIPPING...

Page 10: ...towards back of range 4 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm Check that unit is level side to side and front to back The side trim must be 3 8 0 95 cm above countertop If unit is not level repeat step...

Page 11: ...t the following checks h Check top burner ignition See drawing for proper flame height on HI The low flame should light at every port h Check oven bake function bake burner on full power h Check Conve...

Page 12: ..._ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Notes _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __...

Reviews: