Legs are packed in styrofoam top pack.

Note:

Legs should be installed near to where

appliance is to be used, as they are

not secure for long transit.

Note:

It is strongly recommended

that a pallet or lift jack be used rather than tilting.

Raise unit about a foot. Unscrew temporary legs from

couplings on all four corners.

4

Lower range gently to keep any undue strain from

legs and internal mounting hardware.

3

Screw legs into couplings on all

four corners.

Leg Installation

1

2

Measure the four corners in cutout area to verify if

flooring is level.

For uneven or sloped floors, level unit with metal shims

only, as the adjustment required may exceed

the thread available in the leg.

3

4

3/

8”

3/8”

(0.

95

cm

)

(0.95 cm)

3/

8”

(0.

95

cm

)

Move unit into opening.

Leveling/Adjustments/Alignment

5

Check that unit is level side to

side and front to back. Side trim of the high corner

must be 3/8” (0.95 cm) above countertop.

If leveling is required, move unit out of opening.

6

1

2

1

Lift unit and prop on wood blocks.

Summary of Contents for F20513

Page 1: ...Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20513A EN 070208J Viking Installation Guide Professional Freesta...

Page 2: ...property damage All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed WARNING CAUTION Warnings Impo...

Page 3: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qua...

Page 4: ...depth Overall 18 3 4 47 6 cm AHAM VGCC530 17 43 1 cm AHAM VGSC530 15 3 8 39 0 cm Oven volume Total oven capacity 4 0 cu ft Measured to AHAM standards VGCC530 3 7 cu ft Measured to AHAM standards VGSC...

Page 5: ...be 30 76 2 cm min to 36 91 4 cm max above the countertop This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the range hood installation ins...

Page 6: ...al regulators are not required on this range since a regulator is built into each unit at the factory Under no condition bypass this built in regulator Manifold pressure should be checked with a manom...

Page 7: ...Installation section Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film residues and a...

Page 8: ...l mounting hardware 3 Screw legs into couplings on all four corners Leg Installation 1 2 Measure the four corners in cutout area to verify if flooring is level For uneven or sloped floors level unit w...

Page 9: ...ration always check for gas leaks This must be performed by your dealer a qualified licensed plumber or gas service company Leveling Adjustments Alignments cont Connecting Gas Electric WARNING TIPPING...

Page 10: ...towards back of range 4 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm Check that unit is level side to side and front to back The side trim must be 3 8 0 95 cm above countertop If unit is not level repeat step...

Page 11: ...t the following checks h Check top burner ignition See drawing for proper flame height on HI The low flame should light at every port h Check oven bake function bake burner on full power h Check Conve...

Page 12: ..._ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Notes _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __...

Reviews: