PUSH FOR
VIKING
©
HELP
EMERGENCY
PHONE
CONNECTED
CALL
"Call Connected" LED
Push for "Help" Button ("Info" Button
available on model E-1600A-TP2-EWP)
Marine grade 316 stainless steel faceplate
and push button switch (sealed per IP67)
Grade 2 Braille Label
(6) 0.250 diameter counter sunk 82° x 0.410
diameter holes for flathead #10 x 24
tamper-proof screws (not included)
7.750
4.00
2.75
9.50
10.250
0.875
11.75
5.125
Typ
0.75
4.50
2.125
2.75
0.75
Minimum Cutout
5.125
1
3
2
ON
1
2
ON
Ring Connector
(included)
* Earth
Ground
(optional)
1600A Emergency
Phone Board
Rear View of the
E-1600A-TP/TP2/GT-EWP Phone Panel
** Gel-Filled Butt
Connectors
(included)
Note: Polarity Sensitive!
*** Drip
Loop
BLK-4 Control
Module
(included)
(-) Black with
Red stripe
120V AC
(+) Red with
Black stripe
Red (+)
Black (-)
Green
Red with
Yellow stripe
Green with
Yellow stripe
Brown
Gray
Auxiliary Relay Contact Output
(see section D on page 4)
Blue
Blue
Incoming Analog
Phone Line
Phone or Terminal
Device
(not included)
Purple
Orange
Yellow
12V DC
Adapter
(included)
White
White
Disable Feature
(see section E on page 6)
Note: Not polarity
sensitive.
Trigger Input for Optional
Remote Trigger Switch
(see section G on page 4)
+
-
Switched 12VDC Output
(to control lead of optional SL-2)
12VDC Output
(optional SL-2 power)
Negative
Positive
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
A. Wiring
IMPORTANT:
Electronic devices are susceptible
to lightning and power station electrical surges
from both the AC outlet and the telephone line. It
is recommended that a surge protector be installed
to protect against such surges.
B. E-1600A-TP-EWP and E-1600A-TP2-EWP Panel Dimensions
* Note:
To increase surge protection, loosen the PCB
mounting screw labeled (as shown) and fasten a wire
with ring connector (included) from the mounting screw
to Earth Ground (grounding rod, water pipe, etc.)
** Note:
The gel-filled (water-tight) butt connectors are
designed for insulation displacement on 19-26 gauge
wire with a maximum insulation of 0.082 inches. Cut off
bare wire ends prior to terminating.
*** Note:
When wires are routed from above, a “drip loop” is recommended to keep water away from the circuit board.
3
DIP Switch 4 OFF
DIP Switch 4 ON
N.C.
+12VDC Normally ON
COM
+12VDC
N.O.