© 20
10
Viking Preferred Service
8
7
Wiring and Schematics
Wiring Diagram without Dispenser
BU/WH
BK/WH
OR
YL/WH
BR
BK
PK
PK
PK
PK
YL
TN
RD
WH
GN/YL
4
2
3
1
GN/Y
L
TN
RD
WH
YL
FZ THERMISTOR
DEFROST HEATER
DEFROST TERMINATOR
BR
OR
FREEZER COMPARTMENT
GN/YL
PK
PK
WH/BK
VT/WH
FF TOP CAB
GROMMET
BOTTOM OF CABINET
GN/Y
L
PK
WH
GN/YL
VT/WH
WH/BK
WH
WH/BK
PK
BK/WH
BK
WH/BK
BK/WH
BK
CONDENSER
FAN MOTOR
FAN
BRKT
GRD
BR/WH
BR
BK
2
1
BK
2
1
WH
BU
BU
BK
WH
MACHINE COMPARTMENT
2
1
5 4 3
7
6
8
10 9
12 11
13
15 14
WH
2
1
2
1
1
2
1
2
BU
YL
OR
BU/WH
VT
VT/WH
BR
RD/WH
BR/WH
GN/Y
L
WH
BK
WH/BK
RD/WH
RD/WH
WH
PK
PK
WH
RD/WH
PK
PK
TN
WH
RD/WH
YL
YL/WH
BU/WH
VT/WH
OR
BR
YL
YL/WH
BU/WH
VT/WH
OR
BR
2
1
5 4 3
7
6
RD/WH
BR/WH
GN/Y
L
WH
BK
WH/BK
YL
OR
BU/WH
VT
VT/WH
BR
BU
8
10 9
12 11
13
15 14
PK
RD
RD/WH
VT/WH
WH/BK
BR/WH
VT/WH
VT/WH
PK
PK
YL
TN
RD
WH
GN/YL
WH
TN
BK
GN/YL
WH
4
2
3
1
BU/WH
BK/WH
OR
YL/WH
BR
BK
PK
PK
BK
RD/WH
2
2
1
1
4
3
3
4
5
6
5
6
2
2
1
1
4
3
3
4
5
6
5
6
MACHINE COMPARTMENT HARNESS
120 VAC EVAP
FAN SHROUD GRD
GN/Y
L
SOLENOID
GN/YL
WATER VALVE
VT
SERVICE
FAN
BK
RD
WH
CAB
BTM
GROMME
T
TN
WH
TN
VT
VT
GN/Y
L
BK
RD/WH
BK
NC
RD/WH
SWIT
CH
ON/OFF
WH
BK
5
2
GN/YL
BK/WH
BK
1
115 VAC
60 HZ
SERVICE
L
G
N
4
RD
VT/WH
BK
VT/WH
BK
C
NO
NC
PK
GN/Y
L
PK
BK
BK
YL/WH
BK/WH
TOP FF LIGHTS
TOP FZ LIGHTS
BK/WH
VT
FZ LIGHT/ ICE M
AKER SWIT
CH
WITH DOOR OPEN
PK
PK
PK
PK
YL
YL/WH
BU/WH
VT/WH
OR
BR
WH
WH/BK
PK
BK/WH
BK
VT
PK
PK
GN/YL
PK
REMOVABLE CONTROL BOX
1
1
2
2
HIGH VOLTAGE HARNESS
2
YL/WH
BK/WH
1
10
OR/WH
GY
YL
BU/WH
OR
TN
VT
PK
6
3
5
4
8
7
9
BU
GY/WH
LT BU
GN/YL
13
12
11
14
- RED
+ BLK
HIGH VOLTAGE
POWER BOARD
E13-LIGHT RELAY
E12-120 VAC (N)
E11-GROUND
E10-120 VAC (L1)
E9 -120 VAC (N)
E8 -FREEZER LIGHTS
E7 -FRESH FOOD LIGHTS
E6 -DEFROST HEATER
E5 -DEFROST TERMINATOR
E4 -COMPRESSOR
E3 -120 VAC (L1)
E2 -EVAPORATOR FANS
E1 -SERVICE FAN -24 VDC
VT
YL
BK
BU
OR
BR
GN/YL
VT/WH
RD/WH
BK
15
LOW VOL
TA
GE
DISPLA
Y BO
ARD
WH/BK
WH
RD
E2
E6
E1
E8
E5
E7
E11
E12
E10
E13
E4
WH
2
1
10
6
3
5
4
8
7
9
11
12
FRESH FOOD COMPARTMENT
VT
FF FAN
24 VDC
GN/YL
FF FAN COVER
THERMISTER
FF
2
1
BK
RD
1
2
BK/WH
OR/WH
GN/YL
VT
PK
PK
OR/WH
GN/Y
L
BK
VT
BK
WH
BK/WH
PK
PK
OR/WH
WH
BK/WH
VT
V
T/WH
PK
PK
V
T/WH
WH/BK
WH/BK
PK
PK
FZ TOP
GROMMET
V
T/WH
WH/BK
VT
VT
BK
BK
MULLION
PK
PK
RD/WH
RD/WH
WH
LOWER
FF LIGHT
LOWER FZ LIGHT
GRD CAB BOTTOM
GRD LT HOUSING
CAB B
TM GROMMENT
CAB B
TM
GROMME
T
FZ BA
CK
GROMME
T
FZ BA
CK
GROMME
T
GN/YL
GRD LT HSG
WH/BK
FF T
OP
GROMME
T
TOP OF CABINET
GN/YL
FF BA
CK
GROMME
T
GN/YL
WH
WH
WH
GN/Y
L
BK
TN
BK
RD
BK/WH
BK
PK
YL/WH
BU/WH
OR
BR
FZ RIGHT
SIDE
GROMME
T
INVERTER
1
1
3
2
3 2
YL/WH
YL/WH
BK/WH
BU
FF LEFT
SIDE GROMME
T
CAB
GRD
CAB
GRD
CAB
GRD
1
2
1
1
2
LOW VOLTAGE HARNESS
LEFT MOBILITY
PF931030 REV. 3
C
SER
VICE F
AN
CONNEC
TION
PK
GRD FZ LINER
AUTOMATIC
ICE MAKER
GN/YL
WH
GN/Y
L
1
1
FF TOP CAB
GROMMET
VT
OR/WH
BK/WH
RD/WH
2
2
3
3
4
4
5
5
6
6
7
7
WH
BK
8
8
WH/BK
PK
GRD TO LINER
WH
RD/WH
WH
V
T/WH
WH/BK
V
T/WH
WH/BK
V
T/WH
V
T/WH
SVC HTR C
ONNEC
TION
WH/BK
WH/BK
WH
WH
WH/BK
WH/BK
WH/BK
BK
RIGHT MOBILITY
MULLION HTR
FF DOOR LIGHT
SWIT
CH WITH
DOOR OPEN
WH/BK
WH
WH/BK
WH/BK
WH/BK
WH
WH
WH
BK
BK
WH
BK
FLOAT SWITCH
DRAIN PAN HEATER
WH
BK
WH
BK
WH
BK
1 2 1 2
24V DC PCI
2
1
1
2
BK
RD
BK
RD