Viking Preferred Service
54
Service Diagnostics and Procedures
Plasma Cluster
The plasma cluster ion air purifier uses ions to
eliminate airborne bacteria, mold spores, and food
odors without having to be replaced.
1. To access the plasma cluster, remove air cover
(
see fresh food fan procedure
).
2. With cover removed, remove the double sided
tape securing the plasma cluster to the air
cover, disconnect wiring, and repair/replace
plasma cluster.
3. Reverse procedure to reinstall.
The Plasma Cluster is protected by a diode.
Resistance readings should be 2.0 M
Ω
in one
direction and infinite ohms in the other.
Water Filter
The Side-by-Side unit uses a water filter to remove
contaminates from the water supplied to the end
user.
To access the water filter:
1. Open the Fresh Food door, locate the filter
door in the bottom center of the cabinet, and
press in on filter door to open.
2. Turn the filter clockwise to release. Side
pressure on the filter may be necessary to
release the suction and allow filter removal.
3. Reverse procedure to reinstall.
Plasma Cluster
Water Filter
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. Wires removed during disassembly must be replaced on proper terminals to insure
correct earth ground and polarization. After servicing, reconnect power using power switch.