WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. Wires removed during disassembly must be replaced on proper terminals to insure
correct earth ground and polarization. After servicing, reconnect power using power switch.
Service Diagnostics and Procedures–Disassembly
Inverter
The unit uses a power inverter to convert the
AC line signal to a 24V DC signal to operate the
compressor.
To access inverter:
1.
Slide unit out for service. Remove securing
screws and lower rear cover.
2.
Remove Inverter securing screws and
disconnect wiring.
3. Repair or replace inverter.
4. Reverse procedure to reinstall.
Condenser Fan
Need description.
1.
Slide unit out of service. Remove securing
screws and lower rear cover
(see inverter
section at left, step 1).
2.
Remove condenser fan securing screws and
disconnect wiring.
3. Repair or replace condenser fan.
4. Reverse procedure to reinstall.
Screw
Inverter