background image

S1

1

2

ON

3

11

10

9

8

7

6

5

4

3

2

1

* Gel-Filled Butt

Connectors (included)

Note: Polarity Sensitive!

(-) Black with 

White stripe

120V AC

(+) Red with
Black stripe

(+) Black 

* Gel-Filled Butt

Connectors

(included)

Red (+)

Red (+)

Black (-)

Black (-)

Rear View of the

Strobe Light (included)

Red with 

Yellow stripe

Green with 

Yellow stripe

Brown

Gray

LDB-3 Control Module 

(included)

Auxiliary

Contact Output

Blue

Blue

Incoming

Analog

Phone Line

Phone or 

Terminal Device

(not included)

Disable Feature (see

Programming section F)

Purple

Orange

Yellow

N.C.
COM.
N.O.

12V DC

Adapter

Included

(-) Black with 

White stripe

2.75”

(2) #8-32 x 2 1/2 Phillips

Head Self Tapping Screws 

(included)

(2) #10-32 x 5/8

Phillips Head Self

Tapping Screws

(included)

Strobe Light

(included)

B. Front Mounting Without Weatherproof Box

The 

BLK-3-EWP

Strobe Light Kit may be mounted with-

out using the included weatherproof box.  To mount the
strobe light from the front, use the diagram below.

To mount the strobe light from the rear, use the
diagram below.

C. Rear Mounting Without Weatherproof Box

P

P

r

r

o

o

g

g

r

r

a

a

m

m

m

m

i

i

n

n

g

g

Strobe Light

(included)

Wall, post, etc.

2. Loop/Off-hook Indication Only

The 

LDB-3

control module must be placed between the phone line and the phone/terminal device to be monitored. Connect the

incoming line to the red and green wires with the yellow stripe and connect the phone/terminal device to the brown and gray
wires as shown. 

3. Both Ring and Loop/Off-hook Indication

If the application requires ring and loop/off-hook indication, the 

LDB-3

control module must be placed between the phone line

and the phone/terminal device to be monitored.  Connect the incoming line to the red and green wires with the yellow stripe, con-
nect the phone/terminal device to the brown and gray wires.

1. Ring Indication Only

Connect the incoming line to the red and green wires with the yellow stripe as shown in the diagram.  No phone/terminal device
is required.  The 

LDB-3

control module can monitor for ringing any place along the ringing line.

B. Configuring for Ring and/or Loop/Off-Hook Indication

A. DIP Switches

Sw 1

ON

OFF

ON

Sw 3

OFF

ON

ON

Description

Ring Detection Only (see section 

B

).

Off-Hook/Loop Current Detection Only (see section 

B

).

Ring and Off-Hook/Loop Current Detection (see section 

B

).

Sw 2

ON

OFF

Ring Cadence Mode (see section C)

Ring Cadence Mode ON - relay remains activated in between rings.

Ring Cadence Mode OFF - relay is activated only during ringing.

Red

Black

To LDB-3

Control
Module

(included)

Red

Black

To LDB-3

Control
Module

(included)

S1

1

2

ON

3

11

10

9

8

7

6

5

4

3

2

1

1
2
3

ON

* Note:

The gel-filled (water tight) butt connectors

are designed for insulation displacement. Do not
strip wires prior to terminating.

Note:

The phone and

incoming line connec-
tions are NOT polarity
sensitive.

C. Ring Cadence Mode

DIP switch 

2

is used for switching between different ring detection modes.  In the 

OFF

position, the relay and switched 12VDC out-

put will activate only while ring voltage is present and will turn off between rings.  In the 

ON

position,  the relay and switched 12VDC

output will remain on for up to 5.75 seconds after the ringing has stopped.  This allows the relay and 12VDC (flashing strobe light)
to remain on between rings of a standard ring cadence.  

Note:

To use the Ring Cadence Mode, ring detection MUST be enabled

(DIP switch 

1

ON

).

Summary of Contents for BLK-3-EWP

Page 1: ...59 The kit includes 1 LDB 3 control module 1 blue strobe light 1 12V DC power adapter 13 gel filled butt con nectors and 1 single gang weatherproof mounting box with gaskets and hardware LDB 3 control module comes with Enhanced Weather Protection EWP EWP products are designed to meet IP66 Ingress Protection Rating see DOD 859 Durable polycarbonate lens Long life 1 million candle power blue strobe ...

Page 2: ... 715 386 8666 to determine possible causes for the problem The customer MUST be able to step through recommended tests for diagnosis 2 If the Technical Support Product Specialist determines that the equipment is defective based on the customer s input and troubleshooting a Return Authorization R A number will be issued This number is valid for fourteen 14 calendar days from the date of issue 3 Aft...

Page 3: ... line and the phone terminal device to be monitored Connect the incoming line to the red and green wires with the yellow stripe con nect the phone terminal device to the brown and gray wires 1 Ring Indication Only Connect the incoming line to the red and green wires with the yellow stripe as shown in the diagram No phone terminal device is required The LDB 3 control module can monitor for ringing ...

Page 4: ...steps below when using the BLK 3 EWP in conjunction with a surface mounted E 1600 20A A VE 5x5 sur face mount box is required see DOD 424 E 1600 20A and VE 5x5 not included F Disable Feature By connecting the Disable Info Switch input of the LDB 3 control module to the Info switch of Viking s E 1600 20A E 1600 20A EWP E 1600 52A or E 1600 52A EWP Emergency Phone any outbound call initiated from th...