4.3a   PACKING OF LIFEJACKET WITH HALKEY ROBERTS 

INFLATOR

 

1.   Place the lifejacket on a table.

     

 

 Close the CO

2

-cylinder cover and wrap the  

elastic band around it. 

 

2.    Fold up the bottom section on the right hand 

side of the buoyancy chamber.

 

3.   Fold the left section towards the middle.

 

4.    Fold the right section like a fan with the inflator 

on top.

 

5.   Close the cover on the right hand side.

     

 

 IMPORTANT: The release line must protrude 
from the cover.

 

6.   Fold up the bottom section on the left hand side.

 

7.   Fold the right section towards the middle.

 

8.    Fold the left section towards the middle with the 

inflator on top.

 

9.   Close the cover on the left hand side.

    

 

 IMPORTANT: The release line must protrude 
from the cover.

 

10. Fold the neck like a fan with the welding visible.

 

11. Close the cover in the middle of the top.

 

12. Fold in the corners. The welding must be visible.

 

13. Close the cover completely.

4.3a   PACKING OF LIFEJACKET WITH HAMMER INFLATOR

 

1.  Place the lifejacket on a table.

 

2.   Fold up the bottom section on the right hand 

side of the buoyancy chamber.

 

3.    Fold the right section of the buoyancy chamber 

under the inflator.

 

4.   Fold the left section towards the middle, the 

inflator must be visible.

 

5.   Close the cover on the right hand side.

     

 

 IMPORTANT: The release line must protrude 
from the cover.

 

6.  Fold up the bottom section on the left hand side.

 

7.  Fold the right section towards the middle.

 

8.  Fold the left section towards the middle.

 

9   Close the cover on the left hand side.

     

 

 IMPORTANT: The release line must protrude 
from the cover.

 

10. Fold the neck like a fan with the welding visible.

 

11. Close the cover in the middle of the top.

 

12. Fold in the corners. The welding must be visible.

 

13. Close the cover completely.

4.4a   REPLACEMENT OF CO

2

-CYLINDER AND BOBBIN  

(HALKEY ROBERTS INFLATOR) 

 

 After use in fresh water dry the lifejacket. If the 
lifejacket has been used in salt water, it must be 
rinsed with fresh water before drying. Deflate the 
lifejacket using the oral inflation valve.

 

1.   Unscrew the automatic holder (8) and dispose 

the bobbin (7). Carefully rinse the holder in fresh 
water and dry it.

 

2.  Unscrew the used CO

2

-cylinder and dispose it.

 

3.   Place a new bobbin (7) in the inflator. Screw the 

automatic holder onto the inflator.

 

4.   The green indicator (9) must be visible inside the 

automatic holders.

 

5.   If the release arm (3) has been pulled out, press 

it back into position and place the indicator clip 
(4) over the release arm.

 

6.   Gasket (2) under the CO

2

-cylinder must be  

removed and disposed. Insert a new gasket 
in the inflator (5). Place it at the bottom right of 
the inflator.

 

7.    Screw the CO

2

-cylinder (1) into the inflator and 

manually tighten.

4.4b   REPLACEMENT OF CO

2

 CYLINDER AND HYDROSTA-

TIC INFLATOR

Please see enclosed instructions from Hammar.

5. 

SPARE PARTS

 

Halkey Roberts inflator:

 

 The bobbin, CO

2

-cylinder and indicator clip come in 

sets. Do not open until required for use.

 

 It is recommended to keep a spare set.

 

Complet set, item no.: 

 

1037918                    

 

Indicator clips, item no.: 

 

1013530                     

 CO

2

-cylinder, item no.: 

 

1037351

 

Hammar inflator:

 

 CO

2

-cylinder and spare parts for inflator, delivered 

separately. Do not open until required for use.

 

It is recommended always to keep a spare set.

 

The above set has item No.:   

1037916

 
 

Light:

 

Light, item no.: 

 

1040395 / 1040396

6. STORAGE

The lifejacket should be stored in a dry place, possibly  
suspended on a hanger in a closet. Unintended inflation 
may occur due to a combination of moisture and 
vibration. Annual service can reduce the risk of  
unintended inflation.

7. 

APPLICATIONS AND LIMITATIONS

The lifejacket has been tested in water temperatures 
ranging from 0°C to -30°C. At water temperatures below 
zero, automatic inflation may be delayed. If so, release 
it manually. 

Do not ever wear any clothing over VIKING SOLAS 90N. 
If worn together with an immersion suit or any special 
clothing such as sailors’ wear with buoyancy, the 
functioning of the lifejacket may be affected.

Please note that a lifejacket fitted with Hammar inflators 
only inflates automatically when immersed into water 
deeper than 10 cm.

Summary of Contents for Automatic 90N

Page 1: ...01 www viking life com e mail viking viking life com VIKING SOLAS Redningsvest lifejacket Gilet de sauvetage Barn Child Enfant Automatisk Automatic Automatique 90N Godkendt iht 96 98 EC Approved acc to 96 98 EC Approuvé selon la directive 96 98 CE da Brugervejledning en User Instructions fr Instructions d utilisation ...

Page 2: ...4 2 4 3 1 1 2 3 4 5 6 7 4 3a 1 2 3 4 5 6 7 8 ...

Page 3: ...5 9 10 11 12 13 4 3b 1 2 3 4 5 6 7 8 ...

Page 4: ...16 9 10 11 12 13 9 8 7 4 5 2 1 3 4 4a ...

Page 5: ...e til VIKING LIFE SAVING EQUIP MENT A S Bemærk Hvis vesten er udstyret med Halkey Roberts udløsere skal tabletterne udskiftes hvert år efter vesten er taget i brug Der må ikke anvendes tabletter som er over 4 år fra produktionsdatoen Produktionsdatoen er påtrykt tabletten 4 1 KONTROL AF REDNINGSVESTEN FØR BRUG Redningsvest med Halkey Roberts udløser 1 Kontroller at vesten er hel Pust evt vesten op...

Page 6: ...or 9 er kommet til syne i bunden af automatikholderen 5 Hvis der er rykket i udløserarmen 3 skub da denne på plads og isæt indicator clips 4 ved udløserarmen 6 Pakningen 2 under CO2 patronen skal fjernes og kasseres Ny pakning 2 monteres i udløser huset 5 Pakningen skal helt ned i bunden af udløserhuset 7 CO2 patronen 1 skrues stramt i udløserhuset 5 med hånden 4 4b UDSKIFTNING AF CO2 PATRON OG UD...

Page 7: ...re do not ever inflate the lifejacket by mouth prior to automatic or manual inflation 4 MAINTENANCE Maintenance of your lifejacket is essential to your safety if an emergency situation should occur The lifejacket must be serviced annually by a VIKING certified servicing station please contact VIKING LIFE SAVING EQUIPMENT A S for addresses Note If the lifejacket is equipped with a Halkey Roberts in...

Page 8: ...insed with fresh water before drying Deflate the lifejacket using the oral inflation valve 1 Unscrew the automatic holder 8 and dispose the bobbin 7 Carefully rinse the holder in fresh water and dry it 2 Unscrew the used CO2 cylinder and dispose it 3 Place a new bobbin 7 in the inflator Screw the automatic holder onto the inflator 4 The green indicator 9 must be visible inside the automatic holder...

Page 9: ... l un des tubes de gonflage oral AVERTISSEMENT Même s il a été testé afin de supporter une pression excessive ne jamais gonfler le gilet de sauvetage à la bouche avant le gonflage automatique ou manuel 4 MAINTENANCE La maintenance de votre gilet de sauvetage est essen tielle pour votre sécurité en cas d accident Le gilet de sauvetage doit impérativement être remis pour une révision annuelle par un...

Page 10: ...r de la bande élastique 2 Replier la partie inférieure du côté droit de la chambre de flottabilité 3 Replier la partie gauche vers le milieu 4 Plier en éventail la partie droite avec le déclencheur sur le dessus 5 Fermer la housse du côté droit IMPORTANT Le cordon doit impérativement dépasser de la housse 6 Replier la partie inférieure du côté gauche 7 Replier la partie droite vers le milieu 8 Rep...

Page 11: ...et de sauvetage dans un endroit sec éventuellement suspendu sur un cintre dans une penderie Un gonflage intempestif peut arriver Ceci peut être dû à une combinaison d humidité et de vibrations En respectant l entretien annuel ce risque est réduit 7 APPLICATIONS ET LIMITATIONS Le gilet de sauvetage a été testé dans des températures d eau allant de 0 C à 30 C Dans des températures d eau inférieures ...

Page 12: ...14 1065402 VIKING 08 16 ...

Reviews: