14
3 Design and Function
2. Technical Data
Accuracy is specified for a period of one year after calibration and at temperatures
of 18 to 28 °C with relative humidity to 80%.
GENERAL
Overload protection: 600V DC or rms. AC for all measuring ranges
3. Process and functional description
DC VOLTAGE
Maximum voltage between terminals
and earthing
CAT II 600 V
Fuse
F250 mA/600 V; F10 A/600 V
Power supply
9V battery, NEDA 1604 or 6F22
Display
LCD, max. display 1999, updates every
2-3 sec.
Measuring method
Dual-slope integration A/D converter
Indication of rage exceeded
„OL“ indication in display
Polarity indication
„-“ for negative polarity
Operating temperature
0 °C bis +40 °C
Storage temperature
-10 °C bis +50 °C
Low battery indication
„- +“ indication „
“ in Display
Dimensions
138 × 69 × 31 mm
Weight
approx. 170 g
Range
Resolution
Accuracy
200 mV
100
μ
V
± 0,5 % of reading ± 2 digits
2 V
1 m V
± 0,5 % of reading ± 2 digits
20 V
10 m V
± 0,5 % of reading ± 2 digits
200 V
100 m V
± 0,5 % of reading ± 2 digits
600 V
1 V
± 0,8 % of reading ± 2 digits
Summary of Contents for V4324