background image

6

MODEL VG06045

INSTALLATION STEPS

A.    INSTALLING THE BOTTOM STRUCTURAL RAIL

Key Note:  There is an arrow marker on the
bottom structural rail (#9). This is the
installation point of the fixed panel holder
(#7). See the chart to determine the

distance from the center of hole to the

finished wall. When placed for the dry fit

process or installation, this sticker should be

on the inside portion of the shower stall.
There is also a marker on the bottom
structural rail (#9) called "Door Side".  This

indicates the door side location.  Note that
part #9 is reversible based off the

configuration desired. This is also the only
side of the rail that can be cut.  Dry fit all
steps prior to installation.

1.     Ensure that the bottom wall mount brackets

(#1A) are on both ends of the bottom

structural rail (#9).  Place the structural rail

into the fixed panel holder (#7) opening.  If

the structural rail is too long, cut it with a

hacksaw until it fits the opening.

       

NOTE: Remove part #1A prior to cutting

and make sure to only cut the door side

portion of the structural rail.

A1

9

FIXED PANEL HOLDER

ARROW MARKER

VIEW FROM THE INSIDE

DIMENSION TO FINISHED WALL

MODEL

48X74

60X74

64X74

50X74

62X74

22 3/4" (577.5mm)

23 3/4" (603mm)

28 3/4" (730mm)

29 3/4" (755.5mm)

30 3/4" (781mm)

9

1A

Summary of Contents for VG06045 Series

Page 1: ...lation of the product These instructions must be observed for safe installation Maintenance and other important non personal injury and non material damage instructions or statements that should be observed It is highly advised to dry fit the unit prior to any installation IMPORTANT SAFETY PRECAUTIONS WARNING 1 VIGO reserves the right to modify update all hardware and glass components based on bet...

Page 2: ...Strip 1pc 1 extra 12 Glass Supports 2pc 13 Hex Screw 1 5 8 6pc 14 Phillips Screw 3 4 1pc 15 Green Plastic Anchor 1pc 16 White Plastic Anchor 6pc 17 Hex Screw Cover 15pc 18 Allen Key Pack 1 pack 19 Door Seal Strip 2pc 1 extra 2 NOTE INSTALLATION MUST BE DONE BY A QUALIFIED LICENSED PROFESSIONAL 1 1 2 1 10 16 12 13 4 16 12 13 1 8 6 1A 1A 9 7 3 3 1A 11 GLASS THICKNESS 10mm 13 13 16 16 16 13 16 1A 5 1...

Page 3: ...84 62 98084 64 ALLEN KEY PACK 18 MISC DIMENSION B FIXED PANEL DIMENSION A DOOR 26 1 2 x 71 1 2 23 3 8 x 72 3 4 HEIGHT 72 3 4 MODEL VG06045XX4873 ADJUSTABLE DIMENSION C WIDTH 46 48 27 1 2 x 71 1 2 24 3 8 x 72 3 4 VG06045XX5073 48 50 32 1 2 x 71 1 2 29 3 8 x 72 3 4 VG06045XX6073 58 60 33 1 2 x 71 1 2 30 3 8 x 72 3 4 VG06045XX6273 60 62 34 1 2 x 71 1 2 31 3 8 x 72 3 4 VG06045XX6473 62 64 72 3 4 72 3 ...

Page 4: ...DIAGRAM BELOW INSTALLATION OF THE SHOWER DOORS BY AN INEXPERIENCED PERSON MAY RESULT IN GLASS BREAKAGE AND CONSEQUENTLY CAUSE PERSONAL INJURY OR DEATH Handle fragile items with care to prevent personal injury or material damage The glass panels are tempered and cannot be cut Never attempt to do so Always rest glass on a level surface BEFORE STARTING Compare items on your invoice with what you have...

Page 5: ...n and may vary depending on the site requirements To prevent damage to the finish you should protect the shower cabin bottom with a cardboard protector before beginning the installation Ensure that there is sufficient structural support behind the shower wall to hold the weight of the shower door If there is insufficient enough support then reinforce the shower walls with wooden studs prior to sho...

Page 6: ...on Note that part 9 is reversible based off the configuration desired This is also the only side of the rail that can be cut Dry fit all steps prior to installation 1 Ensure that the bottom wall mount brackets 1A are on both ends of the bottom structural rail 9 Place the structural rail into the fixed panel holder 7 opening If the structural rail is too long cut it with a hacksaw until it fits the...

Page 7: ...rk the location of the fixed panel holder 7 on the floor using the arrow marker on the structural rail as a guide 3 Remove the structural rail and fixed panel holder Drill holes into the respective marks and insert plastic anchors 16 inside them Not necessary if installing into studs Studs are the preferred means of installation anchors can pull out of the wall causing property damage and bodily h...

Page 8: ...install the fixed panel seal strip 10 on the fixed panel 4 when checking for accurate dimensions Attach the seal strip 10 to the wall side of the front fixed panel 4 Start at the bottom and work your way up using the heel of your hand to firmly press the seal strip onto the glass 5 Install the mounting clips from 1A using hex screws 13 making sure that both sides are level Replace the bottom struc...

Page 9: ...de it back as far as possible from the glass before you tighten The part that connects to the wall should be facing in Be sure to use washers on both sides of the panel WASHERS 12 4 12 10 VIEW FROM THE OUTSIDE VIEW FROM THE SIDE FIXED PANEL HOLDER 7 CAP FIXED PANEL 4 GASKET B2 1A 17 A6 5 Install the hex screw covers 17 to the bottom wall mount brackets 1A If this is not done now the installation o...

Page 10: ...th the center point of the fixed panel holder 7 the fixed panel 4 and the bottom structural rail 9 should be parallel prior to attaching the fixed panel to the wall 4 Remove the front fixed panel Drill holes into the respective marks and insert plastic anchors 16 inside them Not necessary if installing into studs Studs are the preferred means of installation anchors can pull out of the wall causin...

Page 11: ... PANEL 4 HEX SCREW 5 Screw the fixed panel to the wall with the with 1 5 8 screws 13 6 Replace the fixed panel holder face plate cap to the fixed panel holder by screwing the cap back on from the other side of the glass B5 16 13 4 7 4 VIEW FROM THE OUTSIDE CAP B6 4 ...

Page 12: ...ening 2 Position the top roller guide 2 onto the fixed panel Position the structural rail correctly using a level Mark the location of the wall mount brackets 1 on the wall The height of the center of the wall mount brackets should be 73 1 4 NOTE The measurement of 73 1 4 should just be used as a guide Your actual dimension may vary C1 C INSTALLING THE TOP STRUCTURAL RAIL 2 1 8 1 4 C2 TOP ROLLER G...

Page 13: ...13 Not necessary if installing into studs Studs are the preferred means of installation anchors can pull out of the wall causing property damage and bodily harm Note The housing to the top wall mount bracket assembly 1 will need to be unthreaded in order to install the mounting clips 4 Replace the structural rail and slide mounting brackets against the wall Tighten the hex screws NOTE There is a 1...

Page 14: ...s at the bottom of the door panel 5 Fully tighten the screws and re install the roller cover Repeat steps 1 and 2 for the other roller 3 Cut the door bottom seal strips 11 according to the chart on the following page to accommodate the configuration and size of your unit Install the door bottom seal strips 11 onto the bottom of the door panel 14 MODEL VG06045 D1 D2 D3 ROLLER 3 ROLLER HEIGHT ADJUST...

Page 15: ... 3 4 14 9 16 3 3 8 3 3 8 4 1 8 RIGHT DOOR INSTALLATION LEFT DOOR INSTALLATION 48X74 50X74 60X74 62X74 64X74 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 3 3 4 3 3 8 3 3 8 4 1 8 MODEL SIZE ...

Page 16: ...ses to the wall Start at the bottom and work your way up using the heel of your hand to firmly press the seal strip onto the glass 5 The door seal strips must all meet each other properly to avoid any leakage Please note that seal strip 19 will be installed in Step E D4 D5 10 11 19 10 11 5 11 5 19 ...

Page 17: ...lls that are not 100 plumb The bottom screw on the face of the roller adjusts the height of the ball bearing inside You may need to remove door unit from install to modify height It will also require two people One person to hold the glass in the closed position while the other loosens the roller height adjustment screw and tightens when the glass is in the desired position Please refer to pages 2...

Page 18: ...E HANDLE 1 Unscrew the handle holders from the handle assembly 6 2 Install the handle as shown Make sure to have gaskets between any metal and glass F1 F2 E INSTALLING THE WATER SEAL STRIP 1 Attach the door seal strip 19 to the door and to the fixed panel respectively Start at the bottom and work your way up using the heel of your hand to firmly press the seal strip onto the glass E1 This end must...

Page 19: ...en the floor and the fixed front panel G1 H1 H INSTALLING COVERS 1 Install screw covers 17 to the unit 2 If you haven t already done so install the roller covers There is no need to install silicone between the roller cover and the roller Applying silicone here will not allow for future height modification ROLLER 3 ROLLER HEIGHT ADJUSTMENT SCREW ROLLER COVER 1A 17 1 17 H2 ...

Page 20: ...to remove IMPORTANT 1 DO NOT use abrasive cleaners scrapers metal brushes or any items that could scratch or dull the surface 2 DO NOT allow surface to come in contact with acetone nail polish remover dry cleaning solution lacquer thinner gasoline or other similar products REGULAR CARE AND MAINTENANCE OF YOUR VIGO SHOWER ENCLOSURE Your home is a moving entity shifting and settling over time Vigo u...

Page 21: ...e rollers should be adjusted as shown in Fig 4 FIG 1A IMPORTANT NOTE These adjustments are approximate You may need to adjust the roller height adjustment screw to meet your needs NOTE There is an adjustment on the roller to accommodate walls that are not 100 plumb The bottom screw on the face of the roller adjusts the height of the ball bearing inside Loosen this screw adjust to desired closed do...

Page 22: ...he highest position A B The roller height adjustment screw is in the highest position The roller height adjustment screw is in the lowest position 22 MODEL VG06045 STRAIGHT WALLS TOP ANGLED WALL FIG 3 FIG 2 BOTTOM ANGLED WALL ROLLER A ROLLER HEIGHT ADJUSTMENT SCREW ROLLER B ROLLER HEIGHT ADJUSTMENT SCREW WALL DIRECTION BOTTOM ANGLED FIG 4 HIGHEST LOWEST ROLLER A ROLLER HEIGHT ADJUSTMENT SCREW ROLL...

Page 23: ...lation guide so that VIGO can execute the warranty specified herein If such access is not available all expenses to provide said access will be the responsibility of the owner end user This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable rules regulations and legislation pertaining to such installation...

Reviews: