15
VIGAS 18 DPA, VIGAS 26 DPA
Gasifying boilers VIGAS
5.2.4 Fuel refill, boiler shutdown (manual),
5.2.5 Boiler shutdown (automatic)
5.3 PARAMETERS SETTING Fuel - WOOD
Choose one option
OFF
Switch off
Fuel refill
⌧
Cancel display driver
▲
Change indicated figure
By pressing „
“ boiler switches off and discharge fan will start running
for 300 s. The time is indicated in the upper left corner. By pr60“
running time of the discharge fan can be exceeded. Using rod open the
chimney flap, than open upper door. Add required amont of fuel. When
finished, close upper door and chimney flap. By pressing „0“ discharge
fan will be switched off. By pressing „ “ refill wil be done, discharge fan
will switch off automatically and blower fan starts.
When exhaust gas temperature drops down under set temperature
(
end) the boiler will automatically shutdown. Sign „END“ will appear
on the display. If you had selected automatic transfer from „WOOD“ to
„PELLETS“
, boiler will start – with pellet ignition mode and boiler
continues heating.
Notification:
If selecting automatic transfer
it is advised to choose (
end)
below 60 °C, for fuel „WOOD“ to burn out completely.
Use graphic driver. To recall display driver press middle ENTER button.
The graphic driver offers options: switch off the boiler, refill the boiler or
cancel driver.
To get to parametres setting mode press
„ENTER“
for 2 seconds, and press ▲button. Parameter
setting depends on the boiler type and its configuration.
By pressing ▲ select parameter, you need to change and press
„ENTER“,
figure starts flashing.
By pressing ▲ select required figure and press
„ENTER“
.
2 sec