Operating instructions

for the system user

VIESMANN

Weather-compensated control unit for a multi boiler system (cascade) and to
control the boiler water temperature:

Vitotronic 300, type CM1E

Vitotronic 300, type CM1I

To control the boiler water temperature of each additional boiler in the cascade:

Vitotronic 100, type CC1E

Vitotronic 100, type CC1I

With BASE E control unit

VITOTRONIC 300

VITOTRONIC 100

5863758 GB

9/2018

Please keep safe.

Summary of Contents for VITOTRONIC 200

Page 1: ...e and to control the boiler water temperature Vitotronic 300 type CM1E Vitotronic 300 type CM1I To control the boiler water temperature of each additional boiler in the cascade Vitotronic 100 type CC1...

Page 2: ...ay only be carried out by authorised contractors Only operate the appliance with suitable fuels Adhere to the electrical connection requirements Modifications to the existing installation may only be...

Page 3: ...ify your gas or electricity supplier and your heating contractor Shut off the electricity supply to the building from a safe place outside the building In case of fire Danger Fire presents a risk of b...

Page 4: ...ted hydrocarbons e g as contained in paints sol vents or cleaning fluids and excessive dust e g through grinding polishing work Avoid continuously high humidity levels e g through continuous drying of...

Page 5: ...HW frost protection 18 Special operating programs 18 Vitotronic 300 How to set a time program 19 Time programs and time phases 19 Setting time phases 19 Copying the time program to other days of the w...

Page 6: ...d off Control unit controls 41 Vitotronic 300 type CM1E and Vitotronic 100 type CC1E 41 Vitotronic 300 type CM1I and Vitotronic 100 type CC1I 41 Shutting down the heating system 41 Vitotronic 300 With...

Page 7: ...ve 64 Heating circuit 65 Heating circuit pump 65 Cascade 65 Mixer 66 Night setback 66 Open flue operation 66 Room sealed operation 66 Room temperature 66 Safety valve 66 Solar circuit pump 66 Set temp...

Page 8: ...oper execution of the contract The limitation of liability shall not apply if the damage was caused deliberately or through gross negligence or if mandatory liability applies due to product liability...

Page 9: ...func tions of your Vitotronic control unit some terminology is explained This information can be found in chapter Terminology in the Appendix Intended use The device is intended to control only Viess...

Page 10: ...ated control of a single boiler sys tem You can find all information on operation in the Vitotronic 200 operating instructions Single boiler constant control This makes the Vitotronic control unit sui...

Page 11: ...e and time The date and time were set by your heating contrac tor You can change the settings at any time to suit your individual requirements Power failure All settings are saved if there is a power...

Page 12: ...trol units Remote control operating instructions Home screen Displays and settings The home screen provides you with the most fre quently used settings and checks Call up the home screen as follows St...

Page 13: ...y bars at the bot tom of the boiler that are the same colour as the fuel 1 bar corresponds to of the maximum boiler output 2 bars correspond to of the maximum boiler output 3 bars correspond to the ma...

Page 14: ...function Holiday pro gram 26 Service For contractors only Service For contractors only Using you can scroll through the menu Note The menus available depend on your heating system equipment Menu over...

Page 15: ...tion gas or oil and operating data 16 DHW cylinder heating by the boiler is ac tive red and moving Heating of DHW cylinder by solar ther mal system is active red and moving Vitotronic 300 Energy yield...

Page 16: ...en 2 for the Energy cockpit 3 in conjunction with a gas boiler or in conjunction with an oil boiler The operating data is shown e g the Hours run Note To reset the hours run See chapter Calling up inf...

Page 17: ...tion over the year The values set here are only used in the graphs for energy consumption Fuel consumption Factory setting DHW heating 30 Central heating 70 Tap the following on screen buttons 1 If re...

Page 18: ...active Special operating programs The following special operating programs are available according to system equipment Screed drying This function is activated by your contractor Your screed is dried...

Page 19: ...tory set to Auto matic You can set Individual time programs to be the same or different for every day of the week In the main menu you can call up the time programs under Information The following exp...

Page 20: ...phase settings at any time Example For Monday you want to change time phase 2 Start to 19 00 h Tap the following on screen buttons 01 for the Main menu 02 Heating for central heating settings 03 Heati...

Page 21: ...4 Time program 05 Mo for Monday 06 to edit the Time program 07 for time phase 2 08 to delete Time phase 2 09 to confirm 10 to quit the Time program Control unit operation Vitotronic 300 How to set a t...

Page 22: ...etween the time phases for central heating at standard temperature In the holiday program Factory setting 3 C Setting range 3 to 37 C Tap the following on screen buttons 1 If required for the home scr...

Page 23: ...t the Vitotronic 300 By setting the Heating curve you influence the flow temperature provided by the boiler So that your rooms are heated optimally at all outside temperatures you can adjust Heating c...

Page 24: ...at the Vitotronic 300 Deactivate the central heating Operating program The setting is only required where the Heating and DHW or Heating Operating program is set for central heating Tap the following...

Page 25: ...d for the home screen 2 for the Main menu 3 Heating for central heating settings 4 Heating circuit 1 or Heating circuit 2 or Heating circuit 3 5 Comfort mode 6 OFF to switch off Comfort mode 7 to conf...

Page 26: ...y DHW Oper ating program No central heating Frost protection for the boiler and the DHW cylinder is active DHW heating No DHW heating Frost protection for the DHW cylin der is active Setting the Holid...

Page 27: ...1 If required for the home screen 2 for the Main menu 3 Holiday program 4 If required for the heating circuit s to which the Holiday program should apply and then 5 to delete the Holiday program Vitot...

Page 28: ...he Time program for DHW heating This setting can only be made at the Vitotronic 300 Set individual time phases for DHW heating DHW heating is enabled during these time phases DHW heating starts automa...

Page 29: ...set for the second and third time phases These may also be within the first time phase One time DHW heating outside the time program This setting can only be made at the Vitotronic 300 In the DHW hea...

Page 30: ...ing Tap the following on screen buttons 1 If required for the home screen 2 for the main menu 3 DHW for DHW heating settings 4 Time program DHW circulation 5 If required Heating circuit 1 or Heating...

Page 31: ...for operation Brightness for the standby screen Tap the following on screen buttons 1 If required for the home screen 2 for the Main menu 3 Settings 4 Display brightness 5 Brightness operation or Bri...

Page 32: ...fault display of the home screen or the main menu In the main menu only emissions test mode can be activated Only default display operational Settings can only be made on the default display of the ho...

Page 33: ...for Information 4 for Service contact details 5 Relevant entry field 6 Using the virtual keyboard enter your contractor s contact details 7 to confirm Further adjustments Entering the contractor s con...

Page 34: ...the last character entered discards the whole entry 7 to confirm The name assigned to the relevant Heating circuit appears on the home screen in the Main menu and if available on the remote control d...

Page 35: ...See page 34 Contractor contact details See page 32 Signal tone operation See page 32 Display brightness See page 31 Operating data meters These have to be reset separately see page 37 Vitotronic 300...

Page 36: ...ese are shown See chapter Entering names for heating circuits Detailed options for checking the individual groups can be found in chapter Menu overview Tap the following on screen buttons 1 If require...

Page 37: ...ng up a service message Tap the following on screen buttons 1 in the navigation area The service message appears in a list If several messages are present at once the fol lowing menus may appear after...

Page 38: ...oiler water temperature sensor This enables the contractor to be better prepared and may save you unnecessary travelling costs 5 to acknowledge all fault messages 6 Notify your heating contractor Note...

Page 39: ...our contractor if a fault recurs Your contractor will be able to analyse the cause and rectify the fault Note Fault messages from a Vitotronic 100 are not transfer red to the Vitotronic 300 Fault mess...

Page 40: ...e mixers remain set to the control function The burner is switched off when the maximum tem perature set at the control unit is reached Note Ensure that enough heat is being drawn during emis sions te...

Page 41: ...00 type CC1I Example Vitotronic 300 type CM1I B 23 02 17 16 57 1 2 3 A Fig 4 A Display B ON OFF switch Shutting down the heating system Vitotronic 300 With frost protection monitoring For every heatin...

Page 42: ...level minimum system pressure Position of the following components Pressure gauge Vents Water quality requirements Gas boilers Gas shut off valve Oil boilers Shut off valves in the oil lines at the o...

Page 43: ...s Open the gas shut off valve If necessary check with your gas supply utility Fault is displayed Check what type of fault it is Acknowledge the fault see page 38 If necessary notify your contractor Bu...

Page 44: ...correct if required Operating program see page 17 Room temperature see page 22 Time see page 31 Time program central heating see page 23 Heating curve see page 23 Fault is displayed Check what type o...

Page 45: ...s the burner reset button See separate boiler or burner instructions Vitotronic 300 type CM1I and Vitotronic 100 type CC1I Follow the instructions on the display See page 38 Contact your contractor if...

Page 46: ...m set at the control unit has been changed by another control device You can change the operating program on the Vitotronic control unit and Fault are displayed Cause Remedy Heating system fault Proce...

Page 47: ...n a school heating demand exists outside of school times e g for a parents evening No action required This function cannot be influenced via the control unit Once the external changeover no longer app...

Page 48: ...d thereafter Only a qualified heating contractor should clean the inside of a DHW cylinder and the DHW connections If any water treatment equipment e g a sluice or injection system is installed in the...

Page 49: ...s or lines of the appliance or externally installed accessories these must be replaced with special cables or lines Only use Viessmann cables lines as replacement For this notify your qualified contra...

Page 50: ...rs are additives for optimising fuel oil combustion Viessmann pressure jet oil burners do not require combustion improvers as these burners operate with clean and efficient combustion Please note Comb...

Page 51: ...tons and icons in the energy cockpit Solar energy yield call up DHW cylinder heat up condition call up The DHW cylinder is heated by the solar thermal system The DHW cylinder is heated by the boiler G...

Page 52: ...s restore Temporary deactivation of display screen for clean ing For the flue gas inspector only Test mode activation For contractors only Service menu call up Heating circuit naming Buttons and icons...

Page 53: ...l system DHW cylinder temperature Energy consumption and operating data Favourites For faster access to set menus Main menu overview Note Subject to the features of your heating system not all of the...

Page 54: ...me Buzzer Rename heating circuits Heating circuit 1 Heating circuit 2 Heating circuit 3 Factory settings Heating circuit 1 Heating circuit 2 Heating circuit 3 LAN ON OFF Do not adjust Clean screen Loc...

Page 55: ...ing circuit 2 Comfort mode Economy mode Operating program Standby mode Only DHW Heating and DHW Room temperature Reduced room temperature Time program Heating curve Heating circuit 3 Comfort mode Econ...

Page 56: ...am DHW circulation Automatic Individual Note Subject to the features of your heating system not all of the call up options may be available under Infor mation Further details can be called up for any...

Page 57: ...29 Output 52 Feed pump LON subscriber no Inputs extension EA1 Digital input 1 Digital input 2 Digital input 3 External hook up 0 10 V extension EA1 Pump output signal PM1 Flow rate set val pmp PM1 Pum...

Page 58: ...water temperature Flue gas temperature Fuel type Gas type Altitude Maximum boiler water temperature Ionisation current Gas pressure Temperature limiter Burner locked out Internal fault code burner co...

Page 59: ...eed function External hook up External program Operating status Standard heating mode Reduced heating mode Standby mode Time program Room temperature Set reduced room temperature External set room tem...

Page 60: ...utput 22 Only in conjunction with solar control module type SM1 SM1 outp 22 starts Only in conjunction with solar control module type SM1 Sensor 7 Only in conjunction with solar control module type SM...

Page 61: ...e under Block enable boiler Test mode Settings Language Display brightness Brightness operation Brightness standby Date and time Date Time Buzzer Factory settings LAN ON OFF Do not adjust Clean screen...

Page 62: ...ber control unit Information burner Burner Burner hours run Burner starts Burner status Burner stage 1 Burner stage 2 Actual burner output Burner output stage 1 Burner output stage 2 Boiler temperatur...

Page 63: ...tral heating no DHW heating Note An operating program for central heating without DHW heating is only available for systems without a DHW cylinder When central heating is needed hot water is generally...

Page 64: ...for central heating With underfloor heating systems reduced heating mode only yields limited energy savings see Underfloor heating system Room temperature dependent heating mode In room temperature de...

Page 65: ...n C 110 20 20 Outside temperature in C 3 5 1 4 0 2 Fig 6 A Changing the slope The steepness of the heating curve changes B Changing the level The heating curves are shifted in parallel in a verti cal...

Page 66: ...d operation The combustion air is drawn from outside the building Room temperature Standard room temperature Set the standard room temperature for periods when you are at home during the day Reduced r...

Page 67: ...ly available at the draw off points Information on disposal Disposal of packaging Your contractor will dispose of the packaging from your Viessmann product DE Packaging waste is channelled for recycli...

Page 68: ...nder temperatures 16 DHW heating Factory setting 10 Operating program 18 Switching off 30 DHW heating one time 29 DHW hygiene 29 DHW temperature Higher 29 Setting 28 Display backlight 31 Display scree...

Page 69: ...mp Cylinder heating 67 DHW circulation 67 Heating circuit 65 Solar circuit 66 R Reduced room temperature night temperature 10 Reset 34 Room sealed operation 66 Room temperature For reduced heating mod...

Page 70: ...phase changing 20 Time phase deletion 20 Time phases DHW circulation pump 29 Time phases setting 19 Time program DHW circulation pump 29 Setting 19 Time setting 31 Troubleshooting 43 U Underfloor heat...

Page 71: ...71 5863758...

Page 72: ...You can find local contractors on the internet at www viessmann de Viessmann Limited Hortonwood 30 Telford Shropshire TF1 7YP GB Telephone 44 1952 675000 Fax 44 1952 675040 E mail info uk viessmann co...