45
■
"Fuel delivery"
"ON"
/
"OFF"
"Fuel supply"
"ON"
/
"OFF"
■
"Return temperature raising
pump"
"ON"
/
"OFF"
– if temperature
raising pump is available
■
"Output 52 M1"
"open"
/
"control
mode"
/
"closed"
■
"Output 52 M2"
"open"
/
"control
mode"
/
"closed"
■
"Output 50"
"ON"
/
"OFF"
■
"Output 28"
"ON"
/
"OFF"
■
"Output 20 M1"
"ON"
/
"OFF"
■
Time
■
Date
System circuit information (weather-compensated), heating
circuit 1 and heating circuit 2
Select with
|
/
~
.
Heating program:
Heating and DHW
i Heating circ. 1
Continue
HK1
■
"Heating program"
–
"Heating and DHW"
–
"DHW only"
–
"Standby mode"
–
"Economy mode"
–
"Party mode"
–
"Holiday program"
–
"Screed function"
–
"External program"
–
"External hook-up"
■
"Operating status"
–
"Heating mode"
–
"Reduced mode"
–
"Standby mode"
■
"Flow temperature"
■
"Standard room temp."
■
"Reduced room temp."
■
"Party mode"
– if party mode is
enabled
■
"Room temperature"
– actual value,
if a remote control unit is connected
■
"Mixer"
"open"
/
"control
mode"
/
"close"
■
"Heating circuit pump"
"ON"
/
"OFF"
■
"Holiday program"
– if one has been
entered
System circuit information (with constant boiler water
temperature)
Select with
|
/
~
.
Scanning options
Scanning temperatures
(cont.)
5592 598 GB