39
You can alter the heating characteristics if the room temperature does not meet your
requirements for some time.
You alter the characteristics by changing the slope and level of the heating curve.
For more information regarding the heating curve, see page 40.
Observe the modified heating characteristics over several days (if possible, await a
major change in the weather) before making further adjustments.
Make short-term adjustments to the standard room temperature as on page 18.
Make short-term adjustments to the reduced room temperature as on page 19.
Changing the slope and level
For assistance, use the following table.
Heating characteristics
Measures
Example
The living space is
too cold
during the heating season
Adjust the heating curve
slope
to the
next
higher
value (e.g. 1.5)
Slope
1.5
Level
0 K
The living space is
too hot
during the heating season
Adjust the heating curve
slope
to the
next lower
value (e.g. 1.3)
Slope
1.3
Level
0 K
The living space is
too cold
during spring/autumn
and
during the
heating season
Adjust the heating curve
level
to the
next higher
value (e.g. +3)
Slope
1.4
Level
3 K
The living space is
too hot
during spring/autumn
and
during the
heating season
Adjust the heating curve
level
to a
lower
value
(e.g.
−
3)
Slope
1.4
Level
-3 K
The living space is
too cold
during spring/autumn
, but
warm enough during the
heating season
Adjust the heating curve
slope
to the
next lower
value and the
level
to a
higher
value
Slope
1.3
Level
3 K
The living space is
too hot
during
spring and autumn
,
but warm enough during the
heating season
Adjust the heating curve
slope
to the
next
higher
value and the
level
to a
lower
value
Slope
1.5
Level
-3 K
Further adjustments
Modifying the boiler heating characteristics
5592 598 GB