32
If you only want the pellet hopper to be charged at cer-
tain times, you can set the blocking times individually.
Select the times to ensure that there is sufficient fuel
available during the blocking times.
Note
Only adjust the blocking times for the fuel supply if the
pellet supply takes place via a vacuum module.
Setting blocking times
Vac bl times
Select with
Monday-Friday
Monday-Sunday
Saturday-Sunday
Monday
Fig. 28
Press the following buttons:
1.
å
for the "Extended menu".
2.
|
/
~
for
"Charging"
.
3.
d
to confirm.
4.
|
/
~
for
"Vac bl times"
.
5.
d
to confirm.
6.
|
/
~
until the required part of the week or day
appears.
7.
d
to confirm.
Select with
Blocks
(
!
u
0 2 4 6 8 10 12 14 16 18 20 22 24
Blocks
Mo-Su
00:00 - 06:00
?
22:00 - 24:00
u
Fig. 29
8.
|
/
~
to select the time phase.
The relevant time phase is represented by
a number (
!
,
?
,
§
or
$
).
9.
d
to confirm.
10.
|
/
~
to set the start point.
11.
d
to confirm.
12.
|
/
~
to set the end point.
Note
Do not set the blocking time to be longer
than 10 hours. Blocking times in excess of
10 hours will cause a fault display due to
fuel shortage.
13.
d
to confirm.
14.
To set the beginning and end of further time pha-
ses, proceed as described in steps 8 to 13.
To set further time phases at another part of the
week or weekday, proceed as described in steps 6
to 13.
Deleting blocking times
1.
Set the time for the end point to the same time that
was set for the start point.
The display shows "
- - : - -
".
2.
Press
d
to confirm.
§
- -:- - - - -:- -
u
0 2 4 6 8 10 12 14 16 18 20 22 24
?
- -:- - - - -:- -
u
Mo-Fr
Adopt with
OK
Std
Std
Fig. 30
Setting suction wand assignment/blocking suction wands
Note
You can set the wand assignment and blocking times
for pellet supply only for pellet supply with a vacuum
system and when using an automatic changeover unit.
Fuel supply
Vacuum module blocking times
5679252