20
Required settings
If you require central heating, check the following
points:
■
Have you selected the heating circuit?
For information on settings, see chapter "Selecting a
heating circuit" on page 20.
■
Have you set the required room temperature?
For information on settings, see page 20.
■
Have you selected the correct operating program?
For information on settings, see page 21.
■
Have you selected the required time program?
For information on settings, see page 21.
Selecting a heating circuit
If required, the heating of your interior can be split over
several heating circuits.
■
In the case of heating systems with several heating
circuits always first select the heating circuit where
you want to make a change, before inputting any set-
tings.
■
This selection is not possible in heating systems with
only one heating circuit.
Example:
■
"Heating circuit 1"
is the heating circuit for the
rooms occupied by you.
■
"Heating circuit 2"
is the heating circuit for the
rooms of a separate apartment.
Ú
Htg circuit selection
HC2
Was selected
Heating circuit 2
Heating circuit 1
HC1
Economy mode
Select with
(
Party mode
Heating program
Set room temp.
ß
21 °C
Ù
Ú
HC2
Ù
Ú
HC1
Fig. 13
The heating circuits are marked at the factory as
"Heating circuit 1"
(
HC1
) and
"Heating circuit 2"
(
HC2
).
If you or your heating contractor have renamed the
heating circuits (e.g. as "Apartment" or similar), that
title is then displayed instead of
"Heating circuit 1"
(see page 31).
Setting the standard room temperature
Press the following keys:
1.
ä
Repeatedly, until the standard menu is dis-
played.
2.
|
/
~
To select
"Heating"
.
3.
d
To confirm.
4.
Ù
/
Ú
To select
"Heating circuit 1"
(HC1),
"Heat-
ing circuit 2"
(HC2) or
"Heating circuit 3"
(HC3).
5.
|
/
~
For
"Set room temp"
.
6.
d
To confirm.
7.
|
/
~
For the required temperature.
8.
d
To confirm.
"Adopted"
appears briefly on the display.
Central heating
Room temperature
5684 987 GB