Boiler Connections
37
Venting Connection
For detailed installation information and
specific venting requirements,
reference the Vitodens Venting System
Installation Instructions supplied with
the boiler.
Installation Instructions
Vitodens Venting System
CAUTION
Under certain climatic conditions some building materials may be affected by flue products expelled in close proximity to
unprotected surfaces. Sealing or shielding of the exposed surfaces with a corrosion resistant material (e.g. aluminum
sheeting) may be required to prevent staining or deterioration. The protective material should be attached and sealed (if
necessary) to the building before attaching the vent termination. It is strongly recommended to install the vent termination
on the leeward side of the building.
Electrical Connections
Removing the control unit and opening the power pump module
1.
Flip control unit down and out
towards you. The control unit is held
in place with a spring loaded clip
A
.
2.
Slide unit to the left to remove.
3.
Unlock 4 spring loaded lock screws
B
and remove power pump module
cover plate.
Both the control unit and the power
pump module have labels and stickers
containing important information. Read
and follow their respective instructions.
Note on connection of accessories
For details regarding other installation steps required, please reference the
Installation Instructions supplied with the respective approved accessory
part.