85
5784 568 - 03
Vitodens 100-W, B1HA series & B1KA Combi Installation/Service
Additional Information
Maintenance Record
Measurements
Service date:
by:
Service date:
by:
Service date:
by:
Service date:
by:
Service date:
by:
Service date:
by:
Setpoint value
Static pressure
“w.c.
max. 14 “w.c.
Running pressure (supply pressure)
Natural gas
“w.c.
4-14 “w.c.
Liquid Propane gas
“w.c.
10-14 “w.c.
Carbon dioxide content CO
2
at lower end of rated input range
(low-fire)
vol.-%
at upper end of rated input range
(high-fire)
vol.-%
Oxygen content O
2
at lower end of rated input range
(low-fire)
vol.-%
at upper end of rated input range
(high-fire)
vol.-%
Carbon monoxide content CO
at lower end of rated input range
ppm
Never exceed 50 ppm air-free
at upper end of rated input range
ppm
Never exceed 200 ppm air-free